Contracting Officer (90C), VA Medical Center, 3601 S. Sixth Ave, Tucson, AZ 85723

C -- A/E SERVICES, REPLACE FIRE ALARM SYSTEM SOL SOL 678-39-95 DUE 062995 POC Contracting Officer, Pam Hayes, (520)629-4611, Additional Contact, Jim Waterman, (529)629-4610 The project shall engage the services of a Professional Electrical Engineer to furnish the design, prepare construction drawings, specifications, cost estimates, furnish PC workstation with software and furnish construction period services for Project #678-94-101, Replace Fire Alarm System at the VA Medical Center, Tucson AZ. This project encompasses replacement of the existing fire alarm system with a new Class ''B'', Local Building System in Buildings 57, 38, 50, 2, 58, 37, 3, 4 and 1, upgrading existing Local Building Fire Alarm Systems in Buildings 30, 60, and 67, upgrading the Fire Alarm System in Buildings 7, 8, 9, 11, 12, and 13, upgrading the Fire Alarm System in Buildings 5 and 6, upgrading the Fire Alarm System in Buildings 56, 59, and 66 and upgrading the VA Base Loop Fire Alarm System. In addition to Note #24, the following are minimum requirements: A. The engineer responsible for the work on this project shall possess a Bachelor of Science Degree in Electrical Engineering from a University with accreditation of the Electrical Engineering curriculum as a professional engineering curriculum by the Accreditation Board for Engineering and Technology (ABET). B. The engineer shall be currently registered in the State of Arizona as a Proefessional Engineer in Electrical Engineering. C. The Engineer shall have completed the design of at least one Fire Alarm system of similiar complexity that has been sucessfully installed and operated within the past four years. D. The Electrical Engineer responsible for this project shall be a full time employee of the Engineering Company hired for the project. E. All contract drawings shall be prepared by a designer or draftsperson who possesses a minimum of three years experience in the preparation of construction drawings using AUTOCAD computer-aided drafting systems. F. The Electrical Engineer's normal place of business shall be LOCATED WITHIN 60 MILES OF THE VAMC, TUCSON AZ. Submittals of SF 254 and SF255 must be received in this office not later than 6/29/95, 4pm local time. This is not a request for proposal. (0143)

Loren Data Corp. http://www.ld.com (SYN# 0020 19950524\C-0004.SOL)


C - Architect and Engineering Services - Construction Index Page