|
COMMERCE BUSINESS DAILY ISSUE OF JUNE 5,1995 PSA#1360WL/POKA, Bldg 7, 2530 C ST, WRIGHT-PATTERSON AFB OH 45433-7607 A -- INTEGRATED POWER UNIT (IPU) ADVANCED DEVELOPMENT SOL
F33615-95-R-2509 DUE 070795 POC Barbara A. Riley, Wl/POKA,
513-255-2730. Wright Laboratory is interested in receiving proposals
for the research effort described below. This solicitation and
resulting award shall be made in accordance with the Research and
Development Streamlined Contracting Procedures (RDSCP) described in
DFARS 235.70. This is the solicitation, there will be no formal RFP or
RFQ. The name, address and telephone number of the representative of
the contracting officer for this solicitation is shown as POC above.
This solicitation consists of this notice, any subsequent amendments,
and a supplemental package which is available by writing to the above
address. Offerors who did not respond to synopsis POK-95-02 published
94JAN25 should provide, in writing, their complete address information
to Wright Laboratory (see above address) in order to receive any
subsequent amendments and the supplemental package (if applicable). All
of the mandatory terms, clauses and provisions at DFARS 235.7006,
Research and Development Streamlined Contracting format, and the
following optional items are incorporated by reference:
b.3,B.6,B.8,C.2,E.1,E.4,F.1,G.2($105,000.00),G.3,G.4,I.42,I.43,I.47,i.
49,I.53,I.63,I.65,I.67,I.68,I.69,I.70,I.73,I.76,I.82,I.84,I.85i.87,I.8
8,I.94,I.95,I.97,I.100,I.107,I.127,I.128,I.129,I.131,I.132,
i.136,I.138,I.145,I.146,I.147,I.148,I.152,I.153,I.155,I.157,I.159,I
.161,i.163,I.164,I.166,I.169 J.1,J.2,M.1.,M.2 This solicitation
includes clauses and provisions from FAR 1990 edition updated through
FAC 90-25 and DFARS 1991 edition updated through DAC 91-6. Baseline and
Option will both be evaluated using the standard evaluation factors
found in Section M of DFARS 235.7006. The last two technical evaluation
criteria are of equal weighting. A Cost Plus Fixed Fee (Completion)
type contract is contemplated. The estimated period of performance is
58 months commencing on or about 95 SEP 30 which includes 4 months for
writing and reviewing the final report. Contractor shall include in
their cost proposal the estimated cost and fee for each phase of their
proposed effort. For pricing purposes the contractor shall assume an
exercise option date of on or before the conclusion of Phase II. It is
expected that this contract will be awarded based upon a determination
that there is adequate price competition, therefore, the offeror is not
required to submit or certify cost or pricing data with its proposal.
If, after receipt of the proposals, the Contracting Officer determines
that adequate price competition does not exist in accordance with FAR
15.804-3, the offeror shall provide certified cost or pricing data as
required by the Contracting Officer. Request you provide a cost
summary with your cost proposal in a similar format to that reflected
in the supplemental package. To be responsive to this solicitation,
submit an original and eight copies of your Technical proposal no later
than 1500 hours, 95Jul07, addressed to: WRIGHT LABORATORY, BLDG 7,
Attn: BARBARA A. RILEY, WL/POKA, 2530 C ST, AREA B, WRIGHT-PATTERSON
AFB OH 45433-7607. Submit an original and 2 copies of your Cost
Proposal and original and 2 copies of your Small and Small
Disadvantaged Business Subcontracting Plan (if applicable) no later
than 1500 hours, 95Jul21, to the same address. The page limitations for
technical and cost proposals are specified in DFARS 252.235-7006
(L.24). The DD Form 1423, Contract Data Requirements List, requirements
are described as follows: DI-MISC-80711/T, SCIENTIFIC And TECHNICAL
REPORTS--FINAL REPORT, 3 COPIES EACH OF THE DRAFT AND FINAL, And 1 COPY
OF THE REPRODUCIBLE FINAL, DI-F-6004B/T, CONTRACT FUNDS STATUS REPORT
(CFSR), 4 Copies, QUARTERLY, DI-FNCL-80331/T, FUNDS And MAN-HOUR
EXPENDITURE REPORT, 4 COPIES, MONTHLY, DI-MISC-80711/T, SCIENTIFIC And
TECHNICAL REPORTS, 4 COPIES, MONTHLY, DI-MGMT-80368/T, STATUS REPORT,
4 Copies, BI-MONTHLY, DI-MGMT-80615/T, TECHNICAL PROGRESS REPORT, 10
Copies, AS REQ, DI-MGMT-80507A/T, PROJECT PLANNING CHART, 4 Copies,
BI-MONTHLY, DI-ADMN-81373/T, PRESENTATION MATERIAL, 1 VUGRAPH Copy, 2
HARDCOPIES AND 1 DISK Copy, ASREQ, DI-ADMN-81250A/T, CONFERENCE
MINUTES, 2 COPIES, ASREQ, DI-MISC-80169, STILL Photo COVERAGE, 2 COPIES
AND 1 REPRODUCIBLE COPY, ASREQ, DI-A-3027A/T, Data ACCESSION
LIST/INTERNAL DATA, 1 COPY, SEMI-ANNUAL, DI-SAFT-80101A/T, System
SAFETY HAZARD ANALYSIS REPORT, 2 COPIES EACH OF THE DRAFT And FINAL, AS
REQ, DI-DRPR-81002/T, DEVELOPMENTAL DESIGN DRAWINGS And ASSOCIATED
LIST, 1 DRAFT AND 1 FINAL Copy, ONE/R, DI-NDTI-80566/T, TEST PLAN, 2
COPIES EACH OF THE DRAFT And FINAL, ONE/R, DI-NDTI-80604/T, TEST
REPORT, 1 DRAFT And 1 FINAL COPY, ONE/R, DI-MISC-80711/T, SCIENTIFIC
And TECHNICAL REPORTS, 2 COPIES, ONE/R. The technical requirements,
including the reporting requirements, are contained in the supplemental
package. The objective of this effort is to demonstrate the integration
of key technologies for the electric Integtated Power Unit (IPU) Unit.
The main focus of this program will be the integration of a high speed
starter/generator with air breathing turbo-machinery. The key aspects
in the development and demonstration of Integrated Power Unit (IPU)
Advanced Development will be the lubricationless bearing approach
combined with air cooling technology for high speed electric machines
combined to give a simple rugged, durable IPU design. Request offerors
identify any Independent Research and Development (IR&D) programs
conducted within the last three years in the technical areas being
solicited and present any significant results of such projects in your
technical proposal. (0152) Loren Data Corp. http://www.ld.com (SYN# 0002 19950602\A-0002.SOL)
A - Research and Development Index Page
|
|