Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF JUNE 13,1995 PSA#1366

Operational Contracting, 205 W.D Ave., Suite 541, Eglin AFB FL 32542-6862

41 -- CHILLER SOL F08651-95-R-0166 DUE 071495 POC Contact Mary Ann Ham, (904) 882-5165, Contract Specialist, Lonnie Oswalt, Contracting Officer. The Air Force Development Test Center (AFDTC) intends to acquire competitively reconditioned, water-cooled, centrifugal water chiller for use at Eglin AFB, FL. All components shall be new, except the shell. The chiller shall be 200 ton capacity, 460/480 volt, 3 phase, 60 hertz, and it's electrical consumption shall not exceed 0.68 kw/ton at full load. Unit shall have DDC or microprocessor controls with a factory installed line starter. Water shall leave the unit at 45 degrees F and enter at 55 degrees F, with condenser water entering at 85 degrees F and leaving at 95 degrees F. The chiller shall be delivered ready for operation, with a full operating charge of oil and refrigerant that meets current EPA regulations and has an Ozone Depletion Factor of 0.05 or less. Prospective bidders shall furnish the complete historical data of the chiller, including date of original manufacture and original owner. Point of contact for technical issues is Mike Fernandez at (904) 882-4896. Replies to this synopsis should be provided to AFDTC/PKOS, 205 W. D Avenue, Suite 541, Eglin AFB FL 32542-6862. Col Dennis Voss AFDTC/IG (904) 882-5966 has been appointed by the AFDTC Commander to hear offerors' or potential offerors' confidential concerns, if any, regarding this acquisition. His purpose is not to replace the technical staff or contracting officer but to serve as an honest broker and communicate any contractor concern, issues, disagreement personnel. Routine technical and contracting issues should therefore be directed to the technical and contracting staff identified elsewhere in this synopsis. All responsible sources may submit an offer which will be considered. (No contract award will be made on the basis of bids/proposals received in response to this synopsis.) Firms responding to this solicitation should reference F08651-95-R-0166 and indicate whether they are or are not a small or small disadvantaged business concern as defined in FAR 52.219-1 and 52.219-2 and whether they are a manufacturer or dealer/distributor. The Air Force reserves the right to consider a small business set-aside based on responses hereto. Requests for copies of this solicitation must be in writing, or can be faxed to (904) 882-9442. Telephone requests will not be honored. (0160)

Loren Data Corp. http://www.ld.com (SYN# 0271 19950612\41-0002.SOL)


41 - Refrigeration, Air Condition and Air Circulating Equipment Index Page