|
COMMERCE BUSINESS DAILY ISSUE OF june 16,1995 PSA#1369Commanding Officer, Southwest Division, Naval Facilities Engineering
Command, Code 0211, 1220 Pacific Highway, Room 145, San Diego, CA
92132-5187 C -- A-E SERVICES AND PLANS AND SPECIFICATIONS FOR FY98 MCON P-283,
WATER SURVIVAL TRAINING TANK, MARINE CORPS RECRUIT DEPOT, SAN DIEGO,
CALIFORNIA SOL N68711-95-C-7697 DUE 071995 POC Kathy Luhmann/Contract
Specialist, (619) 532-2721, Nancy J. Trent/Contracting Officer, (619)
532-2853. Firm Fixed Price. Architect-Engineer services are required
for cost certification preparation, the design and preparation of plans
and specifications for the purpose of bidding and construction for a
Water Survival Training Tank at MCRD San Diego. Project includes a new
swim tank, 50 meters long X 25 meters wide, toilets, shower
facilities, administrative support, classrooms, storage and mechanical
rooms. Special construction features include seismic design, concrete
piles, sound attenuation and air conditioning. Demolition of existing
structures and possible remediation of contaminated material. The
estimated start date is August 1995. The estimated design completion
date is December 1997. The contract will be negotiated on the basis of
both engineering documentation and design services. Initial award will
only be for the Project Engineering Phase with an option for the Final
Design Phase at a later date. Only authority for synopsis slate and
selection is available at this time. The estimated construction cost is
between $5,000,000 and $10,000,000. A-E selection criteria will include
(in order of importance): (1) recent specialized experience of the firm
(including consultants) in the design of a high bay aquatic training
facilities with indoor 25 meter X 50 meter or larger swimming pool,
large swimming pools on pile foundations, acoustical treatment for
noise attenuation and remediation of asbestos and contaminated ground
water. Do not list more than a total of 10 projects in block 8.
Indicate which consultants from the proposed team, if any, participated
in the design of each project. (2) Professional qualifications of the
staff to be assigned to this project in the design of a high bay
aquatic training facilities with indoor 25 meter X 50 meter or larger
swimming pool, large swimming pools on pile foundations, acoustical
treatment for noise attenuation and remediation of asbestos and
contaminated ground water. List only the team member who actually will
perform major tasks under this project, qualifications should reflect
the individuals' potential contributions to this project. (3) Past
performance on contracts with government agencies and private industry
in terms of cost control, quality of work and compliance with
performance schedules. Indicate by briefly describing internal quality
assurance and cost control procedures and indicate team members who
are responsible for monitoring these processes. List recent awards,
commendations and other performance evaluations (do not submit copies).
(4) Location in the general geographic area of the project and
knowledge of the locality of the project, provided that the application
of this criterion leaves an appropriate number of firms given the
nature and size of this project. (5) Capacity to accomplish the work in
the required time. Indicate the firms present workload and the
availability of the project team (including consultants) for the
specified contract performance period and indicate specialized
equipment available and prior security clearances. (6) List the small
or disadvantaged or woman-owned business firms used as primary
consultants or as subconsultants. If a large business concern is
selected for this contract, they will be required to submit a
subcontracting plan that should reflect a minimum 5% Small
Disadvantaged Business of the amount to be subcontracted out. Those
firms which meet the requirements described in this announcement and
wish to be considered, must submit one copy each of a SF 254 and a SF
255 for the firm and a SF 254 for each consultant listed in block 6 of
the firms SF 255. One copy of the submittal package is to be received
in this office no later than 3:00 P.M. Pacific Time on the due date
indicated above. Should the due date fall on a weekend or holiday, the
submittal package will be due the first workday there after.
Submittals received after this date and time will not be considered.
Additional information requested of applying firms: indicate
solicitation number in block 2b, CEC (Contractor Establishment Code)
and/or Duns number (for the address listed in block 3) and TIN number
in block 3, telefax number (if any) in block 3a and discuss why the
firm is especially qualified based on the selection criteria in block
10 of the SF 255. For firms applying with multiple offices, indicate
the office which completed each of the projects listed in block 8 and
list which office is under contract for any contracts listed in block
9. Use block 10 of the SF 255 to provide any additional information
desired. Personal interviews may not be scheduled prior to selection of
the most highly qualified firm. SF 255's shall not exceed 30 printed
pages (double sided is two pages/organizational charts and photographs
excluded, exception: photographs with text will be considered as a
page). All information must be included on the SF 255 (cover letter,
other attachments and pages in excess of the 30 page limit will not be
included in the evaluation process). Firms not providing the requested
information in the format (i.e. listing more than a total of 10
projects in block 8, not providing a brief description of the quality
control plan, not listing which office of multiple office firms
completed projects listed in block 8, etc.) directed by this synopsis
may be negatively evaluated under selection criteria (3). Firms, their
subsidiaries or affiliates, which design or prepare specifications for
a construction contract or procurement of supplies cannot provide the
construction or supplies. This limitation also applies to subsidiaries
and affiliates of the firm. This is not a request for proposal.
Telegraphic and facsimile SF 255's will not be accepted. Site visits
will not be arranged during the submittal period. See Numbered Note(s):
24. (0165) Loren Data Corp. http://www.ld.com (SYN# 0039 19950615\C-0010.SOL)
C - Architect and Engineering Services - Construction Index Page
|
|