COMMERCE BUSINESS DAILY ISSUE OF june 19,1995 PSA#1370Mr. Yaakov Kruthammer, Deputy Administrative Director, Chaim Sheba
Medical Center, Tel Hashomer 52621, Israel 66 -- ISRAEL: ISOTOPIC TOMOGRAPHIC DUAL-HEADED GAMA CAMERA DUE 070795
POC Tel 972-3-530-3030 FAX 972-3-530-3568 The Chaim Sheba medical
Center invites suppliers to submit a quotation for an isotopic
tomographic dual- headed gama camera with following specifications (a)
capabilities: (1) minimum range 400X500 mm, enabling quick and dynamic
tomographic spect and whole-body two - dimentional scans, similar to
elscint's helix model; (2) the camera must have fully automated on-line
body contouring, and step and shoot scanning capabilities; (B)
components: (1) processor with maximum speed similar to intel's 486/66
suppliers must indicate the processor's (2) hard disk with minimum 340
mb; (3) two monitors with following features located at the control
Post (a) color monitor with 21-inch high definition display screen must
state screen resolutions and camera resolutions; (B) computer system
operating monitor. Must state monitor's screen size and its resolution;
(4) head tilt system up to 90-degree angle; (5) head support unit; (6)
arm support unit; (7) leg support unit; (8) touch ruler; (9)
calorimeters: (a) one pair of low heat calorimeters for tinctium and
iodine 123 isotopes, with maximum resolution of at least 7 2 mm in
fwhm; (B) one pair of fan-beam calorimeters with focal distance of 350
mm for tomographic brain spect, minimum resolution of 5 5 mm in fwhm,
and sensitivity of 220 count/min/yci; 10 cart for carrying pair of
calorimeters storage unit for each calorimeter note supplier May offer
two carts for two pairs of calorimeters vice the storage unit;
examination table: (a) table's shape and orientation must be suitable
for spect and whole-body applications; (B) must state range of vertical
movement; (C) circular movement of the table must be maximum 45- degree
angle from zero state must state movement (D) table May be electrically
or mechanically operated (in the event of power outage); (13) remote
monitor attached to the camera or hung on the wall to enable real-time
display of the scan from the color monitor at the control Post; (14)
software: (a) real-time evolving-image of tomographic spect; (B)
three-dimensional tomographic data processing; (C) scatter free
imaging; (15) software must be compatible to other cameras such as
siemens, picker, ge, sopha and elscint; (16) active radial workstation
(E.G. xpert model of elscint) (a) two active radial workstations for
processing three-dimensional spects, must be fast and latest
state-of-the-art; (B) each workstation to include the following
components (1) high-definition color display screen, minimum size
17-inches must state screen resolution; (2) central processor, pentium
model, and high- speed graphic processor for processing spect tests,
as per intel's model 860 processor; (3) optical erasable, with minimum
0.8 gb. (Should this technology be unavailable, the supplier will
commit to replace existing drive with erasable drive in the future; (4)
color digital printer (as codonic's np-1600). The printer should
include software for operation with the camera; (5) ethernet
communication: (C) communication system: the system will be connected
by ethernet company at the isotopic institute, including the cameras
and workstations for (D) software: (1) software for three-dimensional
processing of tomographic data; (2) sortware in ''C'' language for work
by employees of the nuclear medicine institute, with separate outlet
for connection to a text printer; (e) supplier must have a local agent
capable of providing technical support and after-sales service; (F)
the supplier must provide training courses for three system operators,
two physicians and two technicians at the supplier's plant or at the
hospital the technicians' course should be at the same engineering
level as the plant's engineers; (G) the supplier will provid e two
copies each of operation and service manuals; (H) installation:
installation of the camera will be in accordance with Section 6, its
components in accordance with Section 7, and subsections 7 1 and 7.2 of
the contract; (I) warranty: in accordance with Section 8 of the
contract; (J) training: in accordance with Section 7.4 of the contract;
(K) software and hardware updates: the supplier must provide continuous
software updates during the warranty period at the end of which the
supplier will reclassify the non-optional software to the latest
version free of charge tender no: 198/mtz. The offer must include full
fobprice from port nearest to Israel and submitted no later than July
9, 1995 at 14 00 P. M. at tender box number 1, building 64B, Chaim
Sheba medical Center, Tel Hashomer 52621 for additional information
contact Yaakov Kruthammer, Tel 972-3-530-3225, fax: 972-3- 3568 for
assistance, U.S. companies May contact elana shelemay at the Commercial
service, Tel Aviv, Tel 972- 3-510-7213, fax 972-3-510-7215 Please send
a copy of your response to: Commercial Section (FCS TOP), American
Embassy, Tel Aviv, Psc 98 Box 100, APO AE 09830, Refer to T0042..
(0166) Loren Data Corp. http://www.ld.com (SYN# 0395 19950616\66-0001.SOL)