COMMERCE BUSINESS DAILY ISSUE OF JUNE 23,1995 PSA#1374Operational Contracting, 205 W.D Ave., Suite 541, Eglin AFB FL
32542-6862 49 -- DOWN-DRAFT POSITIVE-PRESSURE SPRAY BOOTH SOL F08651-95-B-0080
DUE 070995 POC Contact B. Hochmuth, (904) 882-5169, Contract
Specialist, Contracting Officer, Bonnie Fitch. The Air Force
Development Test Center (AFDTC) intends to solicit competitively for a
drive-through Down Draft Positive Pressure Spray Booth/Oven with an
in-ground concrete pit to support up to 10 ton vehicles / equipment.
Booth must have front and rear swing out doors for drive through of
vehicles/equipment to be placed inside the booth for corrosion
control/painting. Booth must conform to all standards of safety set by
OSHA as well as Federal, State, and local air and environmental
regulations which limit the amount of volatile organic compounds (VOC)
emissions to the atmosphere and future EPA air quality standards into
the year 2010. Size of booth must be a minimum inside dimension of 38
feet L X 16 feet W X 14 feet H and outside dimensions must not exceed
39 feet L X 17 Feet W X 17 Feet H due to size limitations. The booth
must be installed inside a drive-thru-bay with the bay's internal
dimensions being: 40' length, 20' width and 20' height. Bay roll-up
door dimensions are 13' wide by 14' high. Booth must be insulated and
must be constructed of double skin galvanized steel panels, booth must
have upper and lower interior lights, full ceiling filtration, fast
drying heating system, fully automatic control panel, and dry chemical
fire suppression system. A charcoal filtering system to remove VOC
emissions is required. The air flow system must be minimum 10 HP 3
Phase 220/208 VAC industrial type blower motors. Air exchange in the
booth must be a minimum of six times per minute. A fresh air, filtered
breathing system for the technician that meets standards listed above
and OSHA CFR 1910.134 must be installed. The heating system must be
natural gas with stainless steel burners for long life that can produce
1,000,000 BTU/Hr minimum. All demolition, site preparation and
installation will be required as a separate part of work to ensure full
operation upon completion. Although demolition and installation will be
required, it may be necessary to separate it from the supply
requirement, and may be listed as a separate item or awarded as a
separate item. Standard commercial warranty on installation, electrical
components, and mechanical components is required. Required delivery is
to be determined but should be within 12 months after award of
contract. Delivery and installation date will be provided by the
contracting office. Technical questions may be directed to Msgt
McCormick at 904-883-4491. Contracting questions may be directed to
Bonnie Hochmuth at 904-882-5169. Replies to this synopsis should be
provided to AFDTC/PKOS, 205 W. D Ave, Suite 541, Eglin AFB FL
32542-6862. All responsible sources may submit an offer which will be
considered. (No contract award will be made on the basis of
bids/proposals received in response to this synopsis.) Firms responding
to this solicitation should reference F08651-95-B-0080 and indicate
whether they are or are not a small or small disadvantaged business
concern as defined in FAR 52.219-1 and 52.219-2 and whether they are a
manufacturer or dealer/distributor. The Air Force reserves the right
to consider small business set-aside based on responses hereto.
Requests for copies of this solicitation must be in writing, or fax
(904) 882-9442. Telephone requests will not be honored. (0172) Loren Data Corp. http://www.ld.com (SYN# 0392 19950622\49-0001.SOL)