COMMERCE BUSINESS DAILY ISSUE OF JULY 5,1995 PSA#1381National Institutes of Health, Division of Procurement, AB-B, 6120
Executive Blvd., Room 868, Rockville, Maryland 20892 66 -- BIOSTAT Q AND BIOSTAT B SOL 263-95-B(BC)-0138 POC Sheri Lawson,
Contracting Officer (301) 402-3065 or Edward Wilgus, Chief, AB-B (301)
402-3070. A solicitation will be issued for a Biostat Q and a Biostat
B, benchtop fermentation system (from B. Braun Biotech), or equal. The
fermentation systems shall be in accordance with the following
specifications:1) Shall be a Biostat Q Multi-Fermentor-System with the
following minimum required features: Supply cabinet, Gas flow
rotameters, Brushless D.C. motors, Autoclavable stainless steel trays
with carrying cage for two (2) culture vessels and four (4) storage
bottles (two for each vessel), 1000ml glass culture vessels, pH
electrode complete for 1000ml vessel - (shall be for a 12mm diameter
headplate port, shall be 200mm long and have an Ingold gel filled
electrode and connecting cable to supply cabinet, shall include pH 4,
7, and 9, 250ml buffer solutions), pO2 electrode complete for 1000ml
vessel - (shall be for a 12mm diameter headplate port, shall be 220mm
long and be a polarographic Ingold electrode with a plug connection,
shall include a headplate fitting, connecting cable to supply cabinet
and a membrane kit for repair/replacement of membrane), Watson Marlow
peristaltic pumps for liquid additions - (shall be mounted on front
panel and be for acid and alkali, shall be installed in the supply
cabinet of the Biostat Q and have a flow rate (with 2 X 4 mm tubing) of
8mL/min), Digital measurement and control unit (DCU) - (shall include
slots for four (4) measurement boards and four (4) VME bus boards.
Shall include DCU firmware that will provide measurement and control of
temperature, stirrer speed, pH and pO2 and storage of process
parameters in up to four (4) recipes. DCU boards and amplifiers -
(measurement M1 idle board, equipped with a temperature amplifiers
(measurement range of 0 - 150oC, for connection to a Pt 100 sensor), pH
amplifiers (measurement range of 2 -12 pH, for connection to an Ingold
pH probe (or equal)), pO2 amplifiers (measurement range 0 - 100% sat,
for connection of an Ingold pO2 probe (polarographic)). Shall be a
Biostat B with the following minimum required features: Addition agent
pumps shall be for acid, alkali, anti-foam and nutrient feed, shall be
installed in supply cabinet of Biostat B, shall have a configuration
program that assists each pump to operate defined function, shall have
a Watson Marlow peristaltic pump with acid/alkali resistant head, flow
rate for 2 X 4 mm tubing shall be 8 mL/min and 30 mL/min for 4 X 7 mm
tubing. A pH electrode, complete, shall be provided for the B-5 vessel
as follows: shall be for a 12mm diameter headplate port, shall have an
Ingold gel filled electrode, insertion length shall be 317 mm and have
a connecting cable to supply cabinet (100 mm), shall include a
headplate fitting and pH 4, 7, and 9, 250ml buffer solutions). A pO2
electrode, complete, shall be provided for the B- 5 vessel as follows:
shall be for a 12mm diameter headplate port, shall be a polarographic
Ingold electrode with a plug connection, insertion length shall be 312
mm, shall include a headplate fitting, shall include a connecting cable
to supply cabinet (100 mm) and a membrane kit for repair/replacement of
membrane). A foam sensor, complete, shall be provided for the B-5
vessel as follows: shall be for a 6mm diameter headplate port,
insertion length shall be 80 mm, shall have ceramic insulation and
shall include a connecting cable to supply cabinet (100 mm). A level
sensor, complete, shall be provided for the B vessel as follows: shall
be for a 6mm diameter headplate port, insertion length shall be 120
mm, shall have ceramic insulation and shall include a connecting cable
to supply cabinet (100 mm). Digital measurement and control system
(DMCS): shall be for connection of a Pt 100 temperature sensor and have
a measuring range of 0 - 150oC, shall have pH measurement and control
for an Ingold pH electrode and have a measuring range of 2 - 12 pH,
shall have pO2 measurement and control for a polarographic Ingold pO2
electrode with a measuring range of 0 - 100% saturation, shall have
foam measurement and control for connection of a conductive foam sensor
and a limit switch with digital output signal, shall have level
measurement and control for connection of a conductive level sensor and
a limit switch with digital output signal. Shall have standard firmware
DMCS Version 1.1 with the following functions: process delays with
simultaneous display of four (4) process variabled per screen,
measurement and control of: temperature, stirrer speed, pH, pO2 and
antifoam. Solicitation will be issued on or about 15 calendar days
after publication with closing date 30 calendar days after issue date.
(0181) Loren Data Corp. http://www.ld.com (SYN# 0591 19950703\66-0002.SOL)