COMMERCE BUSINESS DAILY ISSUE OF JULY 11,1995 PSA#1385Officer in Charge of Construction, Gulfport/Keesler Area, 100 Annex
Road, Suite 101, Biloxi, MS 39531-3111 Z -- REPLACEMENT OF CHILLERS AT BUILDING 1003, NAVOCEANO, STENNIS
SPACE CENTER, BAY ST. LOUIS, MS Solicitation N62467-95-B-5731 Due
091295 Contact, Mary Reed 601/377-8576/Contracting Officer D.W. Hawkins
601/377-8577. The work to be performed under this project consists of
providing the labor, equipment, and materials to remove two water
cooled chillers, a cooling tower and three condensing water pumps;
purchase and install two chillers, a two cell cooling tower, two pumps,
and piping; construct cooling tower supports; and reconnect electrical
service, controls, and sensors. Chilled water for air conditioning
must be maintained to Building 1003. No total outages will be
permitted. The Contractor shall provide a temporary air-cooled chiller
with a minimum capacity of 525 kw to supply chill water. Only one
chiller will be removed, replaced, and placed in service before work is
begun on the second chiller. Screw type chillers, using 134a
refrigerant, may be used in lieu of centrifugal chillers. As Discrete
Option One - install a tube brush cleaning system on each chiller's
condensing water lines. A Discrete Option Two - Provide a 2 year
maintenance contract on the chillers. As Discrete Option three -
Provide a 5 year maintenance contract on the chillers. Estimated cost
range $250,000 to $500,000. estimated time for completion one
hundred-twenty (120) calendar days. The proposed contract listed here
is being considered for 100 percent set-aside for Small Disadvantaged
Business (SDB) concerns. Interested SDB concerns should, as early as
possible but not later than 11 August 1995, indicate interest in the
acquisition by providing to the contracting office above evidence of
capability to perform the work herein described and a positive
statement of eligibility as a small socially and economically
disadvantaged business concern. Evidence of capacity to obtain required
bonds from an approved surety and specific information which
demonstrates the capabiliy to perform projects of this complexity and
magnitude. Complete informaion concerning management experience in
similar work and current financial statement shall be submitted with
references. Letters of credit from financial institutions WILL NOT be
considered in lieu of a financial statement. However, letters of credit
will be accepted for the purposes of substantiating financial
responsibility. IF THE REQUESTED INFORMATION IS NOT RECEIVED FROM AN
ADEQUATE NUMER OF SDB CONCERNS, THE SOLICITATION WILL BE ISSUED ON AN
UNRESTRICTED BASIS BY AMENDMENT. Even if you have sent the above
information on a prior contract, you must submit documentation that
will become part of this solicitation file. Therefore replies to this
office are requested from all interested business concerns as well as
from Small Disadvantaged Business concerns. (188) Loren Data Corp. http://www.ld.com (SYN# 0306 19950710\Z-0008.SOL)