COMMERCE BUSINESS DAILY ISSUE OF JULY 19,1995 PSA#1391AFFTC/PKAC Directorate of Contracting, 5 S. Wolfe Ave, Edwards AFB, CA
93524-1185 44 -- PURCHASE AND INSTALL AUTOCLAVE SYSTEM SOL F04700-95-R-A016 DUE
083095 POC Beverly Ekimoto, Contract Negotiator, (805) 277-3900 Ext
2239 Robyn Barton, Contracting Officer, (805) 277-3900 Ext 2228. This
acquisition is to furnish all labor, tools, and materials necessary to
install an autoclave system at Bldg 1600, Edwards Air Force Base,
California. This is to include the autoclave system, all minor
construction to facilitate the installation and all training necessary
for six (6) shop personnel to operate and maintain the autoclave
system. The autoclave system will consist of: Internal working diameter
of eight (8) feet; internal working length of sixteen (16) feet;
maximum autoclave pressure requirement of 300 psig; maximum autoclave
temperature of 1,000 degrees fahrenheit; maximum heating rate of 10
degrees F/min non-loaded; silicon controlled rectifier (SCR) controller
heat regulation; electrical method of heating; maximum cooling rate of
ten (10) degrees F/min non-loaded; proportional cooling method
(Government to provide water supply for cooling); twenty-four (24) part
thermocouple jacks to be wired to the control and acquisition system
for alarm, recording, and part temperature control purposes; one (1)
hi-limit thermocouple and one (1) permanent air-temperature
thermocouple used for control, alarm, and recording/acquisition
purposes; proportional vacuum system control; manual valve VAC/OFF/VENT
supply line control; dial supply line gauge; eight (8) vacuum monitor
lines (transducers); two (2) quart liquid nitrogen resin trap; maximum
pressurization (N2 (nitrogen) pressurization to be supplied by the
Government) rate will be from 0 psig to full autoclave pressure in 15
minutes; maximum de-pressurization rate will be from full autoclave
pressure to 0 psig in 10 minutes; minimum autoclave air velocity is 300
ft/min; regulation of mass air-flow at differing internal autoclave
pressures; functional IBM 386 based computer control and data
acquisition system; ASME relief valve and rupture disk; high pressure
switch interlocked to disable inlet valve and open exhaust valve; door
interlock including electrical, pneumatic, and mechanical; hi-limit
temperature controller interlocked to disable heating and start
cooling; ''person-in-clave'' safety device; oxygen analyzer; fresh-air
purge system; door interlock; and visual indication of the oxygen
status. RFP F04700-95-R-A016 will be issued on or about 31 Jul 95 with
a 30-day proposal preparation period. This requirement is 100%
set-aside for small business. SIC Code is 3443 and size standard is 500
employees. Requests for the solicitation may be faxed to (805)
258-9632. Telephone requests to be placed on the mailing list will not
be honored. See Numbered Note(s): 1. (0198) Loren Data Corp. http://www.ld.com (SYN# 0514 19950718\44-0001.SOL)
44 - Furnace, Steam Plant, Drying Equipment and Nuclear Reactors Index Page
|
|