Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF JULY 19,1995 PSA#1391

AFFTC/PKAD Directorate of Contracting, 5 S. Wolfe Ave, Edwards AFB, CA93524-1185

58 -- ENCRYPTION EQUIPMENT SOL F04700-95-B-0024 DUE 090595 POC Donna Chesher, Contract Specialist, (805) 277-3900 x2255 John Lemacks, Contracting Officer, (805) 277-3900 x2253. Edwards Air Force Base has a requirement for the following: 6 each encryption unit, salient characteristics are: telemetry data encryption containing provisions for a plug-in KGV-68 encryption device. Unit must be airborne qualified and must accept the crypt key fill from COMSEC devices. Unit should operate across the plain text and encrypted text domains and be characterized for TEMPEST requirements. Unit should provide the necessary power for a PCM encoder data source as well as the TM transmitter. Unit should contain a plug-in module to allow choice of at least three BIT rates per module, a plug-in crypt hold battery, and crypt key status lamps visible to the user. Unit must contain provisions for erasing the crypto key, automatic disabling of the transmitter prior to and during crypto key fill. Units must be the same footprint as the Microcom SP6-68-005 encryption unit and must be electrically and electronically compatible with existing equipment in the F-16 aircraft. Dimensions must not be more than 4.6 x 3.8 x 2.75 inches and must not weigh more than 50 ounces. Operating temperature must be -30 deg C to +80 deg C. Connectors must be as follows: J1 (power) MS27508E12F35P, J2 (PCM) MS27508E12F35S, J3 (transmitter) MS27508E12F35SA, J4 (fill) MS27508E10F35S. EMI per MIL-STD 461 and MIL-STD 462. Radiated Emission per MIL-STD 461, Method RE02, 14KHz to 10GHz. Humidity per MIL-STD 810C. Acceleration 100g, 3 axes. Also 14 each telemetry transmitters, to observe real time pilot and/or aircraft actions, salient characteristics are: must be manufactured under quality control procedures in accordance with MIL-Q 9858A, and must be airborne qualified. Transmitters must have an internal PROM translator that enables custom selection codes or BCD thumbwheel inputs without the need for additional hardware. Units must be the same footprint as the Microcom T610S transmitter and must be electrically and electronically compatible with existing equipment in the F-16 aircraft. Volume must not exceed 8.8 cubic inches and weight must not exceed 12 ounces. Connectors must be as follows: J1 (power) PTH8-4P or equivalent, J2 (RF output) and J3 (modulation input) SMA female, J4 (channel select) MDM-15S. Turn-on time per IRIG 106-86. Frequency selection in 1 MHz steps. EMI MIL-STD 461 at 28 VDC, IRIG-106 for antenna conducted. Temperature -40 deg C to + 85 deg C. Delivery for both items 90 days ARO. SIC code 3663, size standard 750 employees. Descriptive literature to be submitted with bid. FAX requests for this solicitation will be accepted (805)277-2409. Telephone requests to be placed on the mailing list will not be honored. (0198)

Loren Data Corp. http://www.ld.com (SYN# 0534 19950718\58-0001.SOL)


58 - Communication, Detection and Coherent Radiation Equipment Index Page