COMMERCE BUSINESS DAILY ISSUE OF JULY 21,1995 PSA#1393DynCorp of Colorado, P.O. Box 464, Golden, Colorado 80402-0464 S -- OFFSITE DISPOSAL SERVICES FOR LOW LEVEL AND LOW LEVEL MIXED
WASTES DUE 082595 POC Contact Point, Scott Anderson, 303/966-9645,
Subcontract Administrator, R.L. Ryken, 303/966-8657 The Rocky Flats
Environmental Technology Site (RFETS) is exploring the feasibility of
the use of offsite disposal capacity for low level and low level mixed
waste currently generated and stored at RFETS. Rocky Flats
Environmental Technology Site currently has approximately 5,300 cubic
meters of low level waste in inventory with a projected generation rate
of 8,000 cubic meters over the next 5 years. This low level waste
inventory consists of typical industrial type wastes (e.g.,
combustibles, filters, metal, glass, wastewater treatment sludges,
plastic, etc.) contaminated with alpha emitting radionuclides, which by
definition exist at concentration levels below 100 nanocuries per gram.
The primary radionuclides include plutonium-239, americium-241, and
uranium-235, in addition to common decay products and daughter products
associated with these radionuclides. Rocky Flats Environmental
Technology Site also has approximately 14,000 cubic meters of low level
mixed waste in inventory with a projected generation rate of 4,000
cubic meters over the next 5 years. The low level mixed waste inventory
is similar in physical content to the low level inventory, but
additionally, contains constituents that render the waste hazardous in
accordance with the Resource Conservation and Recovery Act (RCRA).
Common contaminants include volatile and semi-volatile organic
compounds (e.g., carbon tetrachloride, toluene, xylene,
tetrachloroethane) and metal compounds such as chromium, cadmium, lead,
nickel, silver, etc.. Based on the fact that the low level mixed waste
inventory is subject to regulation under RCRA, most of the inventory
must be treated to insure compliance with the Land Disposal Restriction
treatment standards or a ''no-migration'' variance must be obtained.
Current plans call for onsite treatment; however, as a part of this
request for interest, RFETS is also interested in exploring the
feasibility of some sort of treatment/disposal combination. Rocky Flats
Environmental Technology Site is soliciting industry interest in
providing for disposal services at an existing or near term planned
offsite facility for RFETS's low level and low level mixed waste
inventory. Initial responses shall be limited to 5 pages maximum;
pre-printed material, however, may be attached. Responses should
include a description of current and planned capabilities and
capacities for receipt of alpha contaminated low level and low level
mixed waste (including pertinent waste exceptance criteria, analytical
requirements, etc.); a discription of facility specific and receiving
state specific licenses, permits, and other required documentation; a
discussion of current and planned disposal facility regulatory status
(including RCRA permits, Nuclear Regulatory Commission licenses, and
State licenses as appropriate); and an estimate of the unit cost for
disposal of the volumes discussed above. Based on the fact that some
low level, and low level mixed wastes could result from Comprehensive
Environmental, Capital Response, Capital Compensation, and Capital
Liability Act (CERCLA) actions, and based on the Environmental
Protection Agency's ''Offsite Rule'' (58 FR 49201, September 22, 1993),
such existing or future capacity must meet the ''acceptability''
criteria and procedures outlined in the rule. The response should
briefly discuss the facility status with regard to this criteria.
Additionally, it will be necessary to coordinate such current or future
disposal capability with the appropriate low-level waste compact and/or
receiving State to insure that there is no objection to the acceptance
of the out-of-state Department of Energy (DOE) waste. The response
should also discuss past successes and current issues associated with
receipt of DOE waste. Response is required within 15 days of date of
publication of this notice. Be advised that information solicited
hereby will not result in award of a subcontract. Information provided
will be used to determine the feasibility of utilizing offsite
disposal facilities for low level and low level mixed wastes. (0200) Loren Data Corp. http://www.ld.com (SYN# 0106 19950720\S-0023.SOL)
S - Utilities and Housekeeping Services Index Page
|
|