COMMERCE BUSINESS DAILY ISSUE OF AUGUST 1,1995 PSA#1400NASA, George C. Marshall Space Flight Center, Procurement Office,
Marshall Space Flight Center, AL 35812 66 -- HYDRAULIC CYLINDERS SOL 8-P-5-16-10354 POC Contact Glynda H.
Meeks, GP24M/Contract Specialist, 205-544-0422, or Jane Maples,
GP24L/Contracting Officer This notice constitutes a Request for
Quotation (RFQ) for Hydraulic Cylinders -- Qty 2 ea -- The cylinders
shall meet the following specifications: Bore 16.000 ins. -- Rod
diameter 8.000 ins -- Stroke 18.0 ins. -- Pressure rating: 5000 psig.
tension, 5000 psig. compression -- Cylinder shall have a clevis mount
on the cap end - The clevis pin shall be 6 inches in diameter (NFPAMP1)
-- Cylinder rod and bore shall be hard chrome plated for wear and
corrosion resistance - Chrome thickness shall not be less than .001
ins. after final honing and polishing -- The rod end shall have 8.0
inches of 6-8 male thread -- Flats or spanner holes shall be provided
near the base of the threads of the threaded rod end to facilitate
installation and removal of adapters on the end of the cylinder rod --
Rod seal, rod wiper and rod bushing shall be retained by a bolted
flange on the cylinder head so removal of these parts does not require
removal of the cylinder head -- Teflon rod and U-cup piston seals
shall be used. Seals shall be mechanically locked to prevent rolling or
blowout -- The piston shall have a bronze filled Teflon or non-metallic
wear band to prevent cylinder scoring and reduce wear -- The rod
bushing shall be of nodular iron or bronze -- The cylinder shall be
provided with SAE-12 ports -- Cushions are not required -- The
manufacturer's name, city, and state; date of manufacturer; pressure
rating; bore; stroke; and rod diameter shall be stamped into metal
plates mechanically attached to the cylinder or shall be stamped
directly into the cylinder in at least 2 locations. Lettering shall be
not less than 3/16 in. tall -- Safety Factors: Must meet ASME Boiler
and Pressure Vessel Code (i.e. must have a 4:1 ultimate factor of
safety at rated pressure). The cylinder is to be used in high load
tests and shock loads are anticipated. The cylinder shall be designed
accordingly -- The cylinder rod end and the cylinder mounting shall be
designed for a minimum ultimate safety factor of 3 and a minimum yield
safety factor of 2 -- The cylinder manufacturer shall provide a written
certificate of performance on the cylinder prior to shipment. The proof
pressure test shall be to 1.5 times the cylinder's pressure rating. The
cylinder shall not leak more than .05 fluid ounce per minute per inch
of bore diameter internally during the test. Additionally, the cylinder
shall not be damaged during the test nor shall it leak externally --
Within 30 days after delivery, MSFC will perform acceptance tests on
the cylinder. Internal leakage shall not exceed .05 fluid ounce per
minute per inch of bore diameter at any pressure less than or equal to
the rated pressure. There shall be no external leakage or cylinder
damage -- F.O.B. Destination -- This notice serves as the only
solicitation; quotes are being requested and a written solicitation
will not be issued -- This procurement is being conducted under the
Simplified Acquisition Threshold (SAT) portion of the Federal
Acquisition Streamlining Act (FASA) -- If the end product(s) quoted is
other than domestic end product(s) as defined in the clause entitled
''Buy American Act -- Supplies,'' the quoter shall so state and shall
list the country of origin -- The quoter shall state in their quote
their size status for this procurement as well as whether they are
minority or woman-owned -- The SIC code and the size standard for this
procurement are 3593 and 500, respectively -- The quoter shall
identify place of performance in their quote -- Questions regarding
this acquisition must be submitted in writing within 5 days after
publication of this notice -- Transmission by facsimile to 205-544-9080
or by Internet e-mail to glynda.meeks@msfc.nasa.gov is acceptable --
Quotations are due 15 days after publication of this notice in the
Commerce Business Daily (CBD) to the address specified above to the
attention of Glynda H. Meeks/GP24M -- Selection and award will be made
on an aggregate basis to the lowest priced, technically acceptable
quoter -- Technical acceptability will be determined by information
submitted by the quoter providing a description in sufficient detail to
show that the product quoted meets the Government's requirement -- The
period of time expected for the Contracting Officer to
solicit/evaluate vendor quotes and issue the purchase order will be
approximately 45 days from publication of this notice in the CBD --
This procurement is a total small business set-aside. (0209) Loren Data Corp. http://www.ld.com (SYN# 0416 19950731\66-0002.SOL)
66 - Instruments and Laboratory Equipment Index Page
|
|