COMMERCE BUSINESS DAILY ISSUE OF AUGUST 16,1995 PSA#1411COMMANDER, USAINSCOM SPT BN (PROV), Attn: IASB-DC-B, 8825 BEULAH ST Ft
BELVOIR VA 22060-5246 66 -- OSCILLOSCOPE SOL DAHC90-95-R-0024 DUE 082895 POC Contact Point,
Alice Kenny, 703/706-2778/Contracting Officer, Scott Crosson,
703/706-2764. The U.S. Army Intelligence and Security Command (INSCOM)
intends to acquire the following laboratory equipment which shall meet
the following specifications: (1EA) Dual Beam, Multiple Trace, Analog
Oscilloscope (and plue in modules). The oscilloscope shall have at
least the following minimum specifications: an eight CM by 10 CM
display CRT. Graticule illumination, graticule readout of control
settings of vertical and horizontal plug-in modules. Two independently
controlled beams, independent external trigger inputs for each beam.
TTL gate A output, Beam 1. TTL gate B output, Beam 2. TTL sawtooth A
output, Beam 1. TTL sawtooth B output, Beam 2. An external trigger A
input, Beam 1. An external trigger B input, Beam 2. Z-Axis A input,
Beam 1. Z-Axis B input, Beam 2. BNC input and output connectors.
Standard 19'' rack mount, and no more than 7 inches high. (8EA) Dual
Trace Vertical Amplifier Unit. Each vertical amplifier shall have at
least the following minimum specifications: 75MHZ bandwidth. Volts per
division range of 5 millivots to 5 volts. Trigger selection switch,
channel 1 or channel 2. Display modes of channel 1, alternate, add,
chop, and channel 2. DC or AC coupled input. BNC connector inputs for
channel 1 and channel 2. Polarity inversion for either channel 1 or
channel 2. (1 EA) Horizontal time base unit. The Horizontal time base
unit shall have at least the following mimimum specifications: time per
division increments of 10NSEC to 5SEC. A times 10 magnifier. An
internal auto, internal normal, and external trigger selection. A
variable threshold control for internal/external trigger adjustment. A
BNC connector for external trigger input. (1EA) Horizontal Time Base
Unit with Delaying Time Base. The horizontal delaying time base unit
shall have at least the following minimum specifications: Time per
Division increments of 10NSEC to 5SEC. Time 10 magnifier. An internal
auto, internal normal, and external trigger selection. Variable
threshold control for internal/external trigger adjustment. BNC
connector for external trigger input. Delay modes of B starts after
delay, and B triggerable after delay. Variable delay control. Trace
separation for double delay. The power requirement is nominally 60HZ,
120 Volts AC. The environmental requirement is nominally 72 degrees at
50 percent humidity. All responsible sources may submit an offer,
which shall be considered by the Agency. Only written or faxed requests
for copies of the solicitation will be accepted. Delivery shall be FOB
Destination, Charlottesville, VA, within 90 days of contract award.
(0226) Loren Data Corp. http://www.ld.com (SYN# 0492 19950815\66-0002.SOL)
66 - Instruments and Laboratory Equipment Index Page
|
|