COMMERCE BUSINESS DAILY ISSUE OF AUGUST 18,1995 PSA#1413Officer in Charge of Construction, Building 1138T1, P.O. Box X7, Marine
Corps Air Ground Combat Center, Twentynine Palms, CA 92278-0107 C -- IQ CONTRACT, ARCHITECTURAL ENGINEERING SERVICES FOR VARIOUS
SEISMIC/STRUCTURAL PROJECTS, MARINE CORPS AIR GROUND COMBAT CENTER,
TWENTYNINE PALMS, CA SOL N68711-95-D-9947. DUE 092595. Contact Mrs.
Merry C. Pilgrim/Contracting Officer, 619-830-7337. This is a firm
fixed price indefinite quantity contract for Architectural-Engineering
Services for Various Seismic/Structural Projects. The services
required may include, but will not necessarily be limited to,
preparation of engineering studies, analyses, reports, final plans,
specifications, and cost estimates for seismic renovation projects or
other projects that are primarily structural in nature as designated.
Typical projects may include but will not necessarily be limited to:
structural and seismic analysis of existing concrete or masonry
buildings, building surveys, soil investigations, material testing,
detailed seismic reinforcement drawings, specifications, cost
estimates, and incidental work from other engineering disciplines
necessary to complete the project. A-E selection criteria is listed in
order of importance and will include: (1) Recent specialized
experience and technical competence of the firm (including consultants)
in the design of seismic retrofitting of concrete and masonry
buildings. Do not list more than a total of 10 projects in Block 8.
Indicate point of contact and telephone number in block 8C for each
project listed. Indicate which consultants from the proposed team, if
any, participated in the design of each project; (2) Professional
qualifications of the staff assigned to the work who must be under the
direct supervision of a Registered Structural Engineer from the State
of California; (3) Capacity to accomplish the work in the required
time. Indicate the firms present workload and the availability of the
project team (including consultants, if any) for the specified contract
performance period; (4) Quality Assurance/Quality Control coordination
methods used during the performance of work; (5) Past performance on
contracts with Government agencies and private industry in terms of
cost control, quality of work, and compliance with performance
schedules. Indicate by briefly describing internal quality
assurance/quality control procedures and cost control procedures. List
recent awards, commendations and other performance evaluations (do not
submit copies); (6) Location in the general geographical area of the
project and knowledge of the locality of the project; provided, that
application of this criterion leaves an appropriate number of qualified
firms, given the nature and size of the project; and (7) Use of Small
or Disadvantaged or Women-Owned business firms as primary consultants
or as subcontractors. The maximum contract value for the base year is
$450,000. The A-E fee for any one project may not exceed $99,000. If
the Government exercises the option to extend the contract, the total
amount of the contract shall not exceed $900,000. The minimum contract
amount (guarantee) will be $22,500. The estimated start date is
December 1995. The estimated completion date is December 1996, with an
option available to the Government to extend the contract for one
additional year until December 1997. A-E firms which meet the
requirements described in this announcement are invited to submit a
completed SF 254 (unless already on file), a SF 255, and a SF 254 for
each consultant listed in block 6 of the firms SF 255 to the office
shown above. Firms responding to this announcement by 4:00 P.M., local
time, 25 September 1995, or the 30th calendar day after the date of
appearance of this announcement in the Commerce Business Daily (CBD),
whichever is later, will be considered. Should the due date fall on a
weekend or holiday, the submittal package will be due the first workday
thereafter. Firms having a current SF 254 on file with this office may
also be considered. This is not a request for proposal. Additional
information requested of applying firms: indicate solicitation number
in block 2b, CEC (Contractor Establishment Code) and/or DUNS number
(for the address listed in block 3) and TIN number in block 3, telefax
number (if any) in block 3a and discuss why the firm is especially
qualified based on the selection criteria in block 10 of the SF 255.
For firms applying with multiple offices, indicate the office which
completed each of the projects listed in block 8 and list which office
is under contract for any contracts listed in block 9. Use block 10 of
the SF 255 to provide any additional information desired. Personal
interviews may not be scheduled prior to selection of the most highly
qualified firm. SF 255's shall not exceed 30 printed pages (double
sided is two pages/organizational charts and photographs excluded,
exception: photographs with text will be considered as a page). All
information must be included on the SF 255 (cover letter, other
attachments and pages in excess of the 30 page limit will not be
included in the evaluation process). Firms not providing the requested
information in the format (i.e. not providing a brief description of
the quality control plan, not listing which office of multiple office
firms completed projects listed in block 8, not providing a list of the
Small or Disadvantage or Woman-Owned business firms used as primary
consultants or as subcontractors, etc.) directed by this synopsis may
be negatively evaluated under the selection criteria in which it was
requested. Firms which design or prepare specifications for a
construction contract or procurement of supplies cannot provide the
construction or supplies. This limitation also applies to subsidiaries
and affiliates of the firm. Telegraphic and facsimile SF 255's will
not be accepted. Site visits will not be arranged during the submittal
period. See Numbered Note(s): 24. (226) Loren Data Corp. http://www.ld.com (SYN# 0016 19950817\C-0005.SOL)
C - Architect and Engineering Services - Construction Index Page
|
|