COMMERCE BUSINESS DAILY ISSUE OF AUGUST 23,1995 PSA#1416Commander, Pacific Division, Naval Facilities Engineering Command,
Contracts Department, Building 258, Pearl Harbor, HI 96860-7300 (Code
0211) C -- ARCHITECT-ENGINEER SERVICES FOR FY98 MCON P-214, FIRE PROTECTION
SYSTEMS, NCTAMS, WESTPAC, GUAM SOL N62742-95-R-0052 POC Contact Ms.
Judy Wong, Contract Specialist, (808) 474-1402 Services include, but
are not limited to design and engineering services for fire protection
systems in three communications building. Project Includes fire
sprinkler system, underfloor carbon dioxide flooding, fire
detection/alarm system, electrical substation, water distribution
system, and water booster pump station with storage tank. If asbestos
or hazardous materials exist, the Architect-Engineer (A-E) contractor
shall identify them and provide for their disposal in the construction
plans and specifications in accordance with applicable rules and
regulations pertaining to such hazardous materials. The selected A-E
may be required to participate in a pre-fee meeting within seven days
of notification and provide a fee proposal within ten days of the
meeting. Initial design and engineering services include preparation of
project engineering documents and participate in a Functional Analysis
Concept Development work session. Follow-on phases may include the
preparation of preliminary design documents, preparation of final
design, post-construction award services; construction surveillance and
inspection services; operational and maintenance support information
services. Estimated construction cost $2,500,000.00 to $5,000,000.00.
Estimated start and completion dates are January 1996 and September
1997, respectively, including review periods. Proposals may be subject
to an advisory audit performed by the Defense Contract Audit Agency.
The following selection evaluation criteria, in relative order of
importance, will be used in the evaluation of A-E firms: (1)
Professional qualifications of firm and staff proposed in design of
fire protection systems for communications building. (2) Specialized
recent experience and technical competence of firm or particular staff
members in design of preaction type fire sprinkler system, automatic
underfloor flooding type carbon dioxide system, and water pump and
storage system. (3) Capacity to accomplish the work in the required
time. (4) Past performance on contracts with Government agencies and
private industry in terms of cost control, quality of work, and
compliance with performance schedules. (5) A-E firm's design quality
control practices/ techniques. (6) Location in the general geographical
area of the project and knowledge of the locality of the project;
provided that application of this criterion leaves an appropriate
number of qualified firms, given the nature and size of the project.
(7) The volume of work previously awarded to the firm by the Department
of Defense shall also be considered, with the object of effecting an
equitable distribution of Department of Defense A-E contracts among
qualified A-E firms and firms that have not had Department of Defense
contracts. (8) Use of Small or Small Disadvantaged or Women-owned Small
Business firms shall also be considered. Subcontracting Plan is
required from large business firm with proposed fee of over
$500,000.00. Each firm's past performance and performance rating(s)
will be reviewed during the evaluation process and can affect the
selection outcome. A-E firms which meet the requirements described in
this announcement are invited to submit complete, updated Standard
Forms 254, Architect Engineer and Related Services Questionnaire, and
255, Architect-Engineer and Related Services Questionnaire for Specific
Project, to the office shown above. A-E firms utilized by the prime A-E
must also submit completed Standard Forms 254 and 255. Only one copy of
each form is required. IN BLOCK 10 AND AN ADDENDUM THERETO, IF
NECESSARY, STATE WHY YOUR FIRM IS SPECIALLY QUALIFIED BASED ON EACH OF
THE ABOVE SELECTION EVALUATION CRITERIA. FOR SELECTION EVALUATION
CRITERION ''(2)'', PROVIDE THE FOLLOWING INFORMATION FOR ONLY THE STAFF
PROPOSED FOR THIS WORK USING THESE COLUMN HEADINGS: ''NAME'', ''RELATED
PROJECTS WORKED ON'', ''YEAR'', ''FIRM'', AND ''TECHNICAL ROLE''. Show
the office location where work will be done and describe the
experience and location of those that will do the work. Firms
responding to this announcement within 30 days from publication date
will be considered. Firms must submit forms to the Contracts Department
by 2:00 p.m. HST, on the closing date. Should the due date fall on a
weekend or holiday, Standard Forms 254 and 255 will be due the first
workday thereafter. This is not a request for a proposal. See Note 24.
(0233) Loren Data Corp. http://www.ld.com (SYN# 0012 19950822\C-0004.SOL)