COMMERCE BUSINESS DAILY ISSUE OF AUGUST 30,1995 PSA#1421Naval Undersea Warfare Center Division, Newport Commercial Acquisition
Department, Code 09, Building 11, Newport, RI 02841-5407 70 -- ATM SWITCH AND ACCESSORIES SOL N66604-95-R-H147 DUE 101695 POC
Contact G. Palmer (401) 841-2442 X292 or W. Oliver Contracting Officer
at (401) 841-2442 X281 FAX: (401) 841-4820 The Naval Undersea Warfare
Center Division, Newport intends to procure the following items by a
Firm-Fixed Price (Supply) contract on a Brand Name or equal basis: 0001
Fore Systems ATM Switch, P/N ASX-200 meeting the following minimum
salient characteristics - compliant with ATM Forum UNI v3.0, IETF and
ITU I.361 (CCITT) standards; 2.5 Gbps throughput; non-blocking; capable
of supporting up to 24 ATM ports per switch; minimum buffer capacity of
13,300 cells per port; minimum port speed 155 Mbps; 19'' rack
mountable; supports 155 Mbps OC-3c/STM-1 multi-mode fiber network
modules; 1 ea., 0002 Fore Systems ATM Network Modules, P/N OC-3c/STM-1
meeting the following minimum salient characteristics - shall be of
type OC- 3c/STM-1, 155 Mbits per second; shall be compliant with ATM
forum STS3c, UNI v3.1, ITU-T I.432, ANSI T1E1.2/93-020, T1S/92-185,
ITU-T G.95, Bellcore TR-NWT-00253, shall provide four ports per module,
modules can operate using multi-mode fiber, connectors shall be of type
SC, 3 ea.; 0003 Fore Systems Silicon Graphics ATM Interface Board, P/N
VMA-200 meeting the following minimum salient characteristics - the
ATM interface board shall operate within a SGI Crimson workstation
running under Irix 5.2, it shall interface to the Crimson workstation
via a VME bus; and shall have a 9u form factor, it shall be fully
compatible and operate with the ATM switch and ATM Network Modules as
described above, it shall support multi-mode fiber with connectors of
type SC; 1 ea., 0004 Operating software for ITEM 000; 1 ea., 0005 Fore
Systems Sun Sparc Station ATM Interface Board, P/N SBA-200 meeting the
following minimum salient characteristics - the ATM interface board
shall operate within a Sun Sparc workstation running under SunOS 4.1.3
and Solaris 2.3; it shall interface to the Sun workstation via S-Bus;
it shall be fully compatible and operate with the ATM switch and ATM
Network Modules as described above; it shall support multi-mode fiber
with connectors of type SC; 4 ea., 0006 Fore Systems HP9000 Interface
Board P/N HPA-200 meeting the following minimum salient characteristics
- the ATM interface board shall operate within a HP 9000 Series 770
workstation running under HP-UX 10.0; it shall be fully compatible and
operate with the ATM switch and ATM Network Modules as described
above; it shall support multi-mode fiber with connectors of type SC; 1
ea. FOB: Destination, NUWC Detachment, New London, CT. Delivery 30
days after award of contract. (0240) Loren Data Corp. http://www.ld.com (SYN# 0319 19950829\70-0002.SOL)
70 - General Purpose ADP Equipment Software, Supplies and Support Eq. Index Page
|
|