Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF SEPTEMBER 1,1995 PSA#1423

Southwest Division, Code 0212, Naval Facilities Engineering Command, 1220 Pacific Highway, Room 135, San Diego, CA 92132-5187

Z -- SPO 95-3, CONVERT TANKS TO JP-8 SERVICE AT THE DEFENSE FUEL SUPPLY POINT, SAN PEDRO, CALIFORNIA SOL N68711-95-B-7686 DUE 103095 POC PLEASE FAX REQUESTS TO MS. JULIE TORRES AT (619) 532-2361. PRESOLICITATION NOTICE - The work is to realign fuel storage Tanks Nos. 11, 14, 17 to accept and issue JP-8 and to provide a tank-bottom water collection system to a new tank located near fuel storage tank No. 17. To realign and isolate Tanks 11, 14 and 17, the fill side will be blinded off from the 250-mm fill line at each fill side valve pit. At each valve pit at each of Tanks 11, 14, and 17, the water draw-off line will be connected and routed to a new 10000-gal. storage tank located near Tank 17. The 50-mm, water draw-off connection will be PVC, double-contained pipe tank bottom. The double-contained pipe will flow draw-off water from Tank 11 toward Tank 17 due to the pressure head developed at Tank 11 and elevation change. A 20-gallon per minute positive displacement pump will be provided at Tank 14. Valve Pit 102, and a centrifugal pump will be provided at Tank 17, Valve Pit 103 to lift the water to the draw-off system. At Valve Pit 108 (VP-108), a new, 300-mm line will be connected to the 460-mm suction line ''N''. The new, 300-mm line will be routed east off D.F.S.P. property to near the center of Gaffey Street, where it will be connected to the existing 300-mm multipurpose line. This line will replace an existing 200-mm line. The 300-mm line will tie into the 460-mm line where the 200-mm line currently is tied in. Valve numbers 17 and 24 (VP-108) will be blinded off and removed from the 460-mm line. At VP-104, valve number 54 will be blinded off on the Valve Pit 108 side. At VP-58, the 200-mm valves in Valve No. 107; VP 59, Valve No. 106; VP-79, Valve No. 110; and VP 81, Valve No. 105, the side closest to the tanks or the downstream side will be blinded off. A new 300-mm pipe inspection tool launcher will be installed on the multipurpose line between the 350-mm JP-4 line and the Chevron line next to the existing 350-mm launchers and the Chevron pipeline shack. The new, 300-mm pipe inspection tool receiver will be located adjacent and north of Valve Pit 108. All underground portions of the 300-mm line will be cathodically protected by galvnic anodes and incidental related work, complete and ready for use.--The estimated cost is between $250,000 and $500,000.--Firm Fixed Price Contract.--Contract duration is approximately 120 calendar days.--This proposed contract is tentatively 100% set-aside for Small Disadvantaged Businesses (SDB).--The Standard Industrial Code is 1629 and the annual size standard is $17 million.--SDB General Contractors must respond in writing no later than 15 days after publication of this advertisement in the CBD.--The written response shall provide the following information: the IFB number N68711-95-B-7686, the firms complete name, address, and phone number, including area code, bonding limitation, capacity, and current availability, the firm's dollar limit for bid guarantee/performance guarantee capacity, provide a minimum of three references with same or similar type work that is currently in progress, or that has been successfully completed.--Lack of detailed responses to the above requested information may result in this solicitation being issued unrestricted.--Tentative issued date on or about 29 October 19954 with an opening date of approximately 30 days later (NOTE: BOD stated above is TENTATIVE). (0242)

Loren Data Corp. http://www.ld.com (SYN# 0090 19950831\Z-0001.SOL)


Z - Maintenance, Repair or Alteration of Real Property Index Page