COMMERCE BUSINESS DAILY ISSUE OF SEPTEMBER 12,1995 PSA#1429U. S. Army Engineer District, Savannah, ATTN: CESAS-EN-EA, P.O. Box 889
(31402-0889) or 100 W. Oglethorpe (31401-3640), Savannah, Georgia C -- DESIGN OF JSTARS CHILD DEVELOPMENT CENTER, ROBINS AFB, GA POC
Derek Cudd at 912/652-5688. 1. CONTRACT INFORMATION: A-E services are
required for site investigation, planning, engineering studies,
concept, preliminary design, final design, and shop drawing review.
This will be a firm fixed price contract. The contract is anticipated
to be awarded in November 1995 and completed in August 1996. The
estimated construction cost range is $1,000,000 to $5,000,000. 2.
PROJECT INFORMATION: A-E Services are required for Design of a 12,000
sf JSTARS Child Development Center, Robins AFB, GA. Subject project
involve design of a single story child development center with a
concrete foundation, floor slab, masonry walls, structural steel frame,
and compatible roof system. Project also includes playground area,
sitework, fire protection, pavements and necesary supporting utilities.
3. PRIMARY CRITERIA: See Note 24 for general process. The selection
criteria in descending order of importance are: a. Specialized
experience in the type of work described in Project Information. The
estimates for this project shall be prepared using the latest Version
of MCACES Gold Software. The software and User's Manual will be
provided by the Savannah District free of charge to the successful A-E.
The drawings will be prepared using graphics created via Microstation
32 or Micro/Station PC (4.0) and/or AutoCADD Version 11. All drawings
delivered to the District that have been created using AutoCADD Version
11 must be translated to .dgn files. The Contractor shall possess the
software to enable the full translation of drawing files from .dwg to
.dgn and vice versa. Before final selection the preselected A-E's may
be required to demonstrate the above compatibility by reproducing a
Government supplied standard drawing and translating it to the
Intergraph format stated above. The method of translation must be
thoroughly described and documented in Block 10 of the SF 255 if the
A-E does not have an Intergraph CADD System. The A-E firm selected will
be required to submit a Design Quality Assurance Plan concurrently with
their fee proposal. Information on what is to be contained in this plan
will be furnished upon notification of selection. Firms responding to
this anouncement are requested not to transmit this plan with their SF
255. b. Past performance on DoD and other contracts with respect to
cost control, quality of work, and compliance with performance
schedules. c. Capacity to accomplish the work in the stated contract
period and to dedicate at least 1 architect, 1 structural engineer, 1
civil engineer, 1 electrical engineer, 1 mechanical engineer and 1 topo
survey crew. The design team must include a Registered Engineer or
Registered Architect who is a full ''member'' in good standing of the
Society of Fire Protection Engineers (SFPE) or an individual who is a
registered Fire Protection Engineer and whose principal duties are Fire
Protection Engineering. d. Professional qualifications of key
management and professional staff members. e. Knowledge of the locality
as it pertains to design and construction methods of single story child
development centers in the geographic area of this project. SECONDARY
CRITERIA: f. Extent of participation of SB, SDB, WO, historically black
colleges and university and minority institutions in the proposed
contract team, measured by percentage of the estimated effort. g.
Location of the firm in the general geographic area of the project. h.
Volume of DoD contract awards in the last 12 months as described in
Note 24. 4. SUBMITTAL REQUIREMENTS: See Note 24 for general submission
requirements. Interested firms having the capabilities to perform this
work must submit ONE copy of SF 255 (11/92 edition) for PRIME and ONE
copy of SF 254 (11/92 edition) for the prime firm and all consultants,
to the above address by 10 October 1995 to be considered for this
selection. Include the firm's ACASS number on the SF 255, Block 3b. For
ACASS information, call 503/326-3459. DEPTH of PRIME and SUBCONTRACTOR
personnel in EACH discipline must be SHOWN in Block 4 of SF 255 and SF
254 to CLEARLY identify the NUMBER of PERSONNEL in each firm and
DISCIPLINE. COVER letters and extraneous materials are NOT desired and
WILL NOT be considered. PHONE calls are DISCOURAGED unless ABSOLUTELY
necessary. PERSONAL visits for the PURPOSE of DISCUSSING this
announcement WILL NOT be scheduled. This is NOT a REQUEST for a
PROPOSAL. (0251) Loren Data Corp. http://www.ld.com (SYN# 0019 19950911\C-0005.SOL)
C - Architect and Engineering Services - Construction Index Page
|
|