Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF SEPTEMBER 14,1995 PSA#1431

Southwest Division, Code 0212, Naval Facilities Engineering Command, 1220 Pacific Highway, Room 135, San Diego, CA 92132-5187

Z -- SPO 9503, CONVERT TANKS TO JP-8 SERVICE ATA THE DEFENSE FUEL SUPPLY POINT, SAN PEDRO, CALIFORNIA SOL N68711-95-B-7686 DUE 103095 POC For Plans and Specs info call 619-532-2082/Contract Specialist, Julie Torres/Contracting Officer, Janet Buyson/Bid Results, 619-532-2355. The work is to realign fuel storage Tanks Nos. 11, 14, 17 to accept and issue JP-8 and to provide a tank-bottom water collection system to a new tank located near fuel storage tank No. 17. To realign and isolate Tanks 11, 14 and 17, the fill side will be blinded off from the 250-mm fill line at each fill side valve pit. At each valve pit at each of Tanks 11, 14, and 17, the water draw-off line will be connected and routed to a new 10,000-gallon storage tank located near Tank 17. The 50-mm, water draw-off connection will be PVC, double-contained pipe tank bottom. The double-contained pipe will flow draw-off water from Tank 11 toward Tank 17 due to the pressure head developed at Tank 11 and elevation change. A 20-gallon per minute positive displacement pump will be provided at Tank 14. Valve Pit 102, and a centrifugal pump will be provided at Tank 17, Valve Pit 103 to lift the water to the draw-off system. At Valve Pit 108 (VP-108), a new, 300-mm line will be connected to the 460-mm suction line ''N''. The new 300-mm line will be routed east off D.F.S.P. property to near the center of Gaffey Street, where it will be connected to the existing 300-mm multipurpose line. This line will replace an existing 200-mm line. The 300-mm line will tie into the 460-mm line where the 200-mm line currently is tied in. Valve numbers 17 and 24 (VP-108) will be blinded off and removed from the 460-mm line. At VP-104, valve number 54 will be blinded off on the Valve Pit 108 side. At VP-58, the 200-mm valves in Valve No. 107; VP 59, Valve No. 106; VP-79, Valve No. 110; and VP 81, Valve No. 105, the side closest to the tanks or the downstream side will be blinded off. A new 300-mm pipe inspection tool launcher will be installed on the multipurpose line between the 350-mm JP-4 line and the Chevron line next to the existing 350-mm launchers and the Chevron pipeline shack. The new, 300-mm pipe inspection tool receiver will be located adjacent and north of Valve Pit 108. All underground portions f the 300-mm line will be cathodically protected by galvanic anodes and incidental related work, complete and ready for use.--The estimated cost is between $250,000 and $500,000.--Firm Fixed Price Contract.--Contract duration is 120 calendar days.--THIS SOLICITATION IS SET ASIDE FOR SMALL DISADVANTAGED BUSINESSES.--The Standard Industrial Code is 1629 and the annual size standard is $17 million.--NOTE: Plans and specs will not be mailed to firms within a 20 mile radius of the issuing office.--Solicitation packages may be acquired in person from Plan Issue or by mail.--Telephone requests will not be accepted.--Requests for the solicitation package must be in writing stating solicitation number N68711-95-B-7686, complete name, address, area code and phone number and whether bidding as a prime/subcontractor/supplier.--Plan holders lists will not be faxed.--Mail requests to Southwest Division, Naval Facilities Engineering Command (Plan Issue), Building 132, 1220 Pacific Highway, San Diego, CA 92132-5187 or fax requests to Plan Issue at (619) 532-2083.--Plans and specifications will be available on or about 29 Sep 1995 until supply is exhausted.--No deposit required. (0255)

Loren Data Corp. http://www.ld.com (SYN# 0195 19950913\Z-0002.SOL)


Z - Maintenance, Repair or Alteration of Real Property Index Page