|
COMMERCE BUSINESS DAILY ISSUE OF SEPTEMBER 22,1995 PSA#1437SOUTHDIV Contracts Office, P.O. Box 9018, Key West, FL 33040-9018 C -- INDEFINITE QUANTITY CONTRACT FOR DESIGN OF ARCHITECTURAL PROJECTS
AT THE NAVAL AIR STATION COMPLEX, KEY WEST, FLORIDA SOL
N62467-95-D-2833. Due 102495. POC Jack Bair, Contracting Officer, (305)
293-2905. Architectural and engineering services for an indefinite
quantity contract for design of architectural projects, repairs and
modernization to shore facilities at the NAS Key West Complex. Projects
may include, but are not limited to, administration facilities,
barracks, housing, light and medium industrial facilities, recreational
facilities and office buildings. Roofing experience is very important.
New construction design work of a primarily architectural nature will
also be considered within the scope of this contract. The various
projects of this contract may require the A/E to conduct comprehensive
asbestos, lead paint, and/or regulated substance surveys and provide
a design which will support their removal/abatement and disposal in
accordance with applicable laws and regulations. Firms unable to accept
work which involves asbestos, lead paint, etc. need not apply.
Experience and qualifications relating to these or similar projects
should be included when responding to this announcement. The duration
of the contract will be one year with a minimum guarantee of $25,000.00
and a Government option to extend one year. The total fees per year
shall not exceed $500,000.00. The following criteria, in relative order
of importance will be used in the evaluation: (1) Professional
qualifications of the proposed design team, including registration of
key team members as Professional Engineers, Registered Architects and
CSI certified specification writers; (2) Specialized experience of the
firm and proposed design team in performing design of repair,
alterations, rehabilitation and modernization to the above mentioned
facilities, this includes experience involving asbestos/lead paint
abatement and use of SPECSINTACT system; (3) Past Performance on
contracts with respect to cost control, quality of work, and compliance
with schedules, including: (a) Government agency/private industry
references, performance ratings and awards, (b) demonstrated long term
relationships and repeat business with Government and private
customers, (c) data on accuracy of cost estimates compared to low bid
and award prices; (4) Aggressive quality control program with proven
results of reducing: (a) review comments during design reviews, (b)
design errors, (c) design omissions, (d) contractual change orders; (5)
Capacity of the firm to accomplish several projects concurrently and
with accelerated time schedules; (6) Geographic location of the firm
relative to Key West and familiarity with the local area or other
semi-tropical coastal environments; (7) Volume of work previously
awarded to the firm by the Department of Defense. Firms will be
evaluated with the object of effecting an equitable distribution of DOD
A/E contracts among qualified firms. In order to be evaluated and
subsequently considered for award all firms must submit the total
dollars awarded to the A/E by DOD during the past 12 months. In-house
capabilities will weigh heavier than work subcontracted. Experience and
proven success working with projects involving asbestos and lead paint
is required. The A/E will be required to provide specifications
utilizing the SPECSINTACT system for specifications and AUTOCAD version
12 for drawings. A-E firms responding should provide their Design
Quality Assurance Plan (DQAP) prior to selection interviews once a
short list has been approved. The DQAP will include an explanation of
the management approach: an organizational chart specifically tailored
to this contract showing the inter-relationship of management and
design team components and specific quality control processes to be
used. Failure to submit all above mentioned data and information will
reflect negatively during the evaluation process. Firms responding
should submit only one copy of qualifications. The qualification
statements must clearly indicate the office location where the work
will be performed and the specific qualifications of the individuals
who will be assigned to work on this contract. This solicitation is
being issued on an unrestricted basis and replies to this notice are
requested from all business concerns. A-E firms which meet the
requirements described in this announcement are invited to submit
completed SF 254 (unless already on file within the last 12 months) and
SF 255 U.S. Government Architect-Engineer Qualification, to the office
stated above. Firms responding to this announcement by 24 October 1995
will be considered. This is not a request for a proposal. See Note 24.
(261) Loren Data Corp. http://www.ld.com (SYN# 0013 19950921\C-0001.SOL)
C - Architect and Engineering Services - Construction Index Page
|
|