COMMERCE BUSINESS DAILY ISSUE OF SEPTEMBER 27,1995 PSA#1440U. S. Army Corps of Engineers, Omaha District, 215 North 17th Street,
Omaha, NE 68102-4978 C -- INVESTIGATION AND DESIGN FOR REMEDIATION OF MISCELLANEOUS
MILITARY AND CIVIL HAZARDOUS, TOXIC, AND RADIOACTIVE WASTE (HTRW) SITES
NATIONWIDE SOL DACA45-96-R-0004 POC For further information, Contact
Laila Berre at: (402) 221-7647. CONTRACT INFORMATION: Up to two
Indefinite Delivery Type contracts may be awarded for a period of one
year and may include options for four additional one year extensions.
Each delivery order issued under this contract will not exceed
$2,000,000. Accumulative Delivery Orders will not exceed $4,000,000 per
year with total contract amount not to exceed $10,000,000. Delivery
Orders will be issued from time to time as the need arises during the
contract period. Delivery orders may be firm fixed price or cost
reimbursable depending on the need. Types of services required will
include site investigations, studies, reports, concept design, final
design (option), and remedial action phase services (option). THE
PROPOSED CONTRACTS ARE 100% SET ASIDE FOR FIRMS CERTIFIED IN THE SMALL
BUSINESS ADMINISTRATION'S SECTION 8(a) PROGRAM. The Standard
Industrial Classification (SIC) code for this requirement is 8744.
Completion date is one year after date of award with an anticipated
start date of April 1996. Submitters are advised that all contracts may
not be awarded if workload does not support their award. PROJECT
INFORMATION: Delivery orders under this contract may include initial
site investigations and assesments, hazard evaluations, field
inspections, environmental assessments or analysis, remedial site
investigations, engineering feasibility studies and reports, remedial
design, UST investigations and reports, remedial action estimates and
checking of remedial action documents (such as shop drawings) for a
variety of HTRW sites throughout the United States. Delivery orders may
also include chemical sampling and analysis, preparation of health and
safety plans, community relations support, environmental permitting
and regulatory compliance. Analytical laboratory facilities will be
required to have or to obtain Missouri River Division Laboratory
validation for biological, chemical and physical testing capabilities.
SELECTION CRITERIA: See Note 24 for general selection process.
Criteria for selection, in order of importance, are: (a) Recent
specialized expeience and technical competence of the firm (including
consultants) in: (1) Performing similar services as outlined above. (2)
Management of cost reimbursable contracts, including explanation of the
firm's cost accounting system. (3) Producing quality products as
evidenced by the firm's quality control procedures. (4) Effective
coordination and management of the project team, including consultants.
(5) Remedial action cost estimating and preparation of estimates on IBM
compatible personal computers using Corps of Engineers Micro-Computer
Aided Cost Estimating System (M-CACES) GOLD version or similar system
(M-CACES software will be provided). (6) Producing Computer Aided
Drafting and Design (CADD) drawings fully compatible with one of the
following: Intergraph Unix System 5 Microstation 32 (version 5.0 or
later, Intergraph MS-DOS Microstation PC (version 5.0 or later). (b)
Professional qualifications and specialized experience in providing
services similar to those listed above of the proposed team members
(including consultants) in the following disciplines: environmental,
geotechnical, chemical, civil, mechanical, electrical and structural
engineering, environmental science (biology, ecology, etc.), chemistry,
geology, hydro geology, toxicology, industrial hygiene, regulatory
compliance, and community relations support. (c) Capacity to accomplish
the work in the required time, including the ability to complete more
than one work order at a time. (d) Past performance as described in
Note 24. (e) Extent of participation of SB, SDB historically black
colleges and universities, and minority institutions in the proposed
contract team, measured as a percentage of the estimated effort. (f)
Volume of DOD contract awards in the last 12 months as described in
Note 24. SUBMITTAL REQUIREMENTS: Solicitation packages are not provided
for A-E contracts. This is not a request for proposal. Firms desiring
consideration shall submit two copies of a combined SF 255 and separate
SFs 254 for prime and each consultant. Also required is a certification
letter from the Small Business Administration that the firm is
certified in the Section 8(a) program. To be considered, submittals
must be sent to the U.S. Army Corps of Engineers and addressed as
follows: Omaha District, A-E Contracts Support Section, ATTN: John M.
Miller, CEMRO-ED-MG, 215 N. 17th Street, Omaha, NE 68102-4978.
Submittals must be received no laterthan close of business on the 30th
day after the date of publication of this announcement. If the 30th
day is a Saturday or Sunday or a federal holiday, the deadline will be
the close of business on the next business day. In block 6 of the SF
255 provide the name and address of the primary analytical laboratory.
In block 10 of the SF 255, provide the following: (a) Design
Management Plan (DMP). The DMP should be brief and include an
explanation of the firm's management approach, management of
subcontractors (if applicable), specific quality control procedures
used and an organizational chart showing the inter-relationship of
management and various team components (including subcontractors). (b)
The firm's present workload and the availability of the project team
(including consultants) for the specified contract performance period.
In block 3 of SF 255 provide the submitting firm's number (six or
seven digits) assigned by the North Pacific Division, U.S. Army Corps
of Engineers, for the Architect-Engineer Contract Administration
Support System (ACASS) and the firm number for any consultants in block
6 of the SF 255. If unknown, so state. To receive information to obtain
an ACASS number, call (503) 326-3459. Personal visits for this
solicitation to the Omaha District offices will not be scheduled.
Administrative and procedural questions shall be directed to John M.
Miller at (402) 221-4176. See Numbered Note(s): 24. (0268) Loren Data Corp. http://www.ld.com (SYN# 0006 19950926\C-0001.SOL)
C - Architect and Engineering Services - Construction Index Page
|
|