COMMERCE BUSINESS DAILY ISSUE OF OCTOBER 17,1995 PSA#1453Westinghouse Electric Corporation Bettis Atomic Power Laboratory P.O.
Box 79, 814 Pittsburgh-McKeesport Boulevard West Mifflin, PA
15122-0079 Y -- PLANTWIDE DOOR REPLACEMENT Sol 73-KZ-726650 Contact Karen Zych,
412/476-7396 The proposed scope of work for the Plantwide Door
Replacement contract includes the replacement of existing doors, door
frames, hardware, etc. at 54 locations in 11 buildings of the
Bettis-Pittsburgh site. New fire rated doors, door frames, hardware,
etc. are to be installed at 40 of the 54 locations. New exterior doors,
door frames, hardware, etc. are to be installed at the remaining 14
locations. This work effort also includes the removal and installation
of alarm and electronic access systems, the repair of adjacent wall
surfaces, the painting of doors, door frames and adjacent wall
surfaces, and the installation of signs, labels, and markers. 1. All
prospective bidder personnel should have U.S. Department of Energy
(DOE) security clearances to attend the on-site pre-bid tour. Uncleared
personnel will be escorted to tour areas where work will be performed,
except those areas determined to be sensitive by Westinghouse.
Attendance at such meetings is essential for proper understanding of
unique ingress/egress procedure and complex site conditions. Also, all
personnel who will be performing on-site work will require a DOE
security clearance. It takes approximately three to five months to
obtain a security clearance after an individual submits a completed and
acceptable ``Questionnaire for Sensitive Position'' (QSP). In this
regard, in order for your company to receive a copy of the RFQ package,
completed QSPs must be submitted to Westinghouse within two weeks from
the date of your request for a copy of the RFQ package. Westinghouse
shall process clearances at no cost to the contractor; however, the
effort to complete and submit QSPs is solely at the contractor's
expense. 2. Prospective bidders must have bonding capability from
sureties listed in the U.S. Treasury Circular 570 relative to contract
performance or be able to provide irrevocable letters of credit from
financial institutions that are Federally insured and have investment
grade or higher rating from a recognized commercial rating service. 3.
This is a small business set-aside action and all prospective bidders
must certify they qualify as a small business. 4. Prospective bidders
must agree to submit a current Foreign Ownership, Control or Influence
Certification and all necessary supporting business and financial
documentation, if requested by Westinghouse. Request for the RFQ along
with the necessary documentation clearly showing your firm meets the
above minimum prerequisites, must be in writing (telephone requests
will not be honored), and your letter must be postmarked no later than
fifteen calendar days after the date of this CBD publication. (286) Loren Data Corp. http://www.ld.com (SYN# 0093 19951016\Y-0002.SOL)
Y - Construction of Structures and Facilities Index Page
|
|