COMMERCE BUSINESS DAILY ISSUE OF OCTOBER 20,1995 PSA#145681 CONS/LGCS, 200 FIFTH STREET, ROOM 104, KEESLER AFB, MS 39534-2102
Attn:/Margarette E. Trone 58 -- RADIO INTERFERENCE DIRECTIONAL FINDING SYSTEM DUE 110195 POC
Margarette E. Trone tel: 601/377-1841/Joy K. Bissonnette, Contracting
Officer, 601/377-3130 CNT F22600-96-R-0006 The Air Force is seeking
potential sources for three (3) each Intercept and Directional Finding
Systems. Equipment will be used in a highly mobile environment. The
system must be able to determine location and source of friendly forces
emitters causing interference, or inadvertent jamming within the HF,
VHF, and UHF spectrums. Equipment must be calibration-certified, easily
maintainable, and ruggedized to MIL STD 810E. It must be a manpack
system and able to run off a battery pack, vehicle battery power, and
AC power. It will consist of direction finding processor, appropriate
antennas to support the HF, VHF, and UHF spectrums (one set
transportable, one set manportable), and associated power sources.
Size: Approximately 4 X 8 X 14 inches, less than 500 cubic inches.
Weight: Less than 50 pounds, with batteries, antennas and associated
cabling. Frequency Range: 1.5 MHZ-2000 MHZ. USB, LSB, CW, AM, NFM
(Narrow), WFM (Wide). Receiver Selectivity: USB/LSB/CW, 2.4 KHZ/-6DB,
4.5 KHZ/-60DB; AM/NFM, 12 KHZ/-6DB, 25 KHZ/-70DB; WFM, 180 KHZ/-6DB,
800 KHZ/-50DB. Audio Output: .5 W @ 10% distortion. Bearing
Display-Circular with back lighting, signal strength display. Measuring
Accuracy: 3% or better. Frequency selection: By keyboard entry in 100
HZ to 100 KHZ steps. Scan Rate: Channels / second. Search Rate: 20
steps/second. Battery Life: Eight hours minimum, rechargeable internal
battery power. Calibration: As recommended by manufacturer.
Transportable receive antennas - no more than three (3) transportable
antennas to cover 1.5 MHZ to 2000 MHG. Manportable receive antennas -
no more than three (3) manportable antennas to cover 1.5 MHZ to 2000
MHZ. Operating Temperature: -20 to 60 degrees Celsius. Operating
Humidity: 5% to 95%. Operating Altitude: 0 to 2500 meters. Storage
Temperature: -30 to 70 degrees Celsius. Storage Humidity: 0% to 95%.
Weather Protection: Rain tight, minimum. This synopsis is for
information and planning purposes only and does not constitute a
solicitation for bids or proposals. Only written responses received
within 15 calendar days from the pulication date will be reviewed.
Prospective offerors should submit brochures to Miss Margarette Trone,
Contract Specialist, at the above address or fax literature to Miss
Trone at 601/377-3298. This requirement will be resynopsized prior to
issuance of a solicitation. Telephone requests will not be honored.
(0291) Loren Data Corp. http://www.ld.com (SYN# 0186 19951019\58-0007.SOL)
58 - Communication, Detection and Coherent Radiation Equipment Index Page
|
|