COMMERCE BUSINESS DAILY ISSUE OF OCTOBER 23,1995 PSA#1457U. S. Army Corps of Engineers, Omaha District, 215 North 17th Street,
Omaha, NE 68102-4978 C -- INVESTIGATION AND DESIGN FOR REMEDIATION OF MISCELLANEOUS
HAZARDOUS, TOXIC, AND RADIOACTIVE WASTE (HTRW) SITES SOL
DACA45-96-R-0008 POC For further information, call Mike Pfeiffer at:
(402) 221-7176. CONTRACT INFORMATION: Up to three Indefinite Delivery
Type contracts may be awarded for a period of one year and may include
an option for two additional one year extensions. Each Delivery Order
issued under this contract will not exceed $2 million with cumulative
amount of contract not to exceed $20 million. Delivery Orders will be
issued from time to time as the need arises during the contract
period. Delivery orders will be from fixed-price. Types of services
required will include site investigations, studies, reports, concept
design, final design and remedial action phase services. The Standard
Industrial Classification (SIC) code for this requirement is 8744.
Contracts will be awarded on an as needed basis based on workload
between April 96 and April 97. Submitters are advised that all
contracts may not be awarded if workload does not support their award.
If a large business is selected for this project, it must comply with
FAR 52.219- 9 regarding the requirement for a subcontracting plan on
that part of the work it intends to contract. This plan is not required
with this submittal. The subcontracting goals for this contract are
that a minimum of 35% of the contractor's intended subcontract amount
be placed with small businesses (SB), including small disadvantaged
businesses (SDB), and 9% be placed with SDB. PROJECT INFORMATION:
Delivery orders under this contract may include initial site
investigations and assessments, hazard evaluations, environmental
assessments or analysis, remedial site investigations, engineering
feasibility studies and reports, remedial design, UST investigations
and reports, remedial action estimates and checking of remedial action
documents (such as shop drawings) for a wide variety of HTRW
contaminated sites located within the Omaha District geographic
boundaries and Air Combat Command projects throughout the United
States. Other sites may be included subject to higher agency approval.
Sites may include all types of contamination and experience in and
knowledge of the complete range of investigation, analysis and
remediation technologies, inluding radiation and radiation analysis
will be required. Delivery orders may also include chemical sampling
and analysis, preparation of health and safety plans, community
relations support, environmental permitting and regulatory compliance.
Analytical laboratory facilities will be required to have or to obtain
Missouri River Division Laboratory validation for biological, chemical
and physical testing capabilities. SELECTION CRITERIA: See Note 24 for
general selection process. Criteria for selection, in order of
importance, are: (a) Recent specialized experience and technical
competence of the firm (including consultants) in: (1) Providing
similar services as outlined above. (2) Producing quality products as
evidenced by the firm's quality control procedures. (3) Effective
coordination and management of the project team, including consultants.
(4) Remedial action cost estimating and preparation of estimates on IBM
compatible personal computers using Corps of Engineers Micro-Computer
Aided Cost Estimating System (M-CACES) GOLD version or similar system
(M-CACES software will be provided). (5) Producing Computer Aided
Drafting and Design (CADD) drawings fully compatible with one of the
following: Intergraph Unix System 5 Microstation 32 (version 5.0 or
later, Intergraph MS-DOS Microstation PC (version 5.0 or later). (b)
Professional qualifications and specialized experience in providing
services similar to those listed above of the proposed team members
(including consultants) in the following disciplines: environmental,
geotechnical, chemical, civil, mechanical, electrical, and structural
engineering, chemistry, biology, geology, hydrogeology, toxicology,
industrial hygiene, regulatory compliance and community relations. (c)
Capacity to accomplish the work in the required time, including the
ability to complete more than one work order at a time. (d) Past
performance as described in Note 24. (e) Extent of participation of SB,
SDB, historically black colleges and universities, and minority
institutions in the proposed contract team, measured as a percentage of
the estimated effort. (f) Volume of DOD contract awards in the last 12
months as described in Note 24. SUBMITTAL REQUIREMENTS: Solicitation
packages are not provided for A-E contracts. This is not a request for
proposal. Firms desiring consideration shall submit two copies of a
combined SF 255 and separate SFs 254 for prime and each conultant. To
be considered, submittals must be addressed as follows: U.S. Army Corps
of Engineers, Omaha District, CEMRO-ED-C, ATTN: John M. Miller, 215 N.
17th Street, Omaha, NE 68102-4978. Submittals must be received no
later than close of business on the 30th day after the date of
publication of this announcement. If the 30th day is a Saturday or
Sunday or a federal holiday, the deadline will be the close of business
on the next business day. In block 6 of SF 255, provide the name and
address of the primary analytical laboratory facility. In block 10 of
the SF 255, provide the following: (a) Design Management Plan (DMP).
The DMP should be brief and include an explanation of the firm's
management approach, management of subcontractors (if applicable),
specific quality control procedures used and an organizational chart
showing the inter-relationship of management and various team
components (including subcontractors). (b) The firm's present workload
and the availability of the project team (including consultants) for
the specified contract performance period. In block 3 of SF 255 provide
the submitting firm's number (six or seven digits) assigned by the
North Pacific Division, U.S. Army Corps of Engineers, for the
Architect- Engineer Contract Administration Support System (ACASS) and
the firm number for any consultants in block 6 of the SF 255. If
unknown, so state. To receive information to obtain an ACASS number,
call (503) 326-3459. Personal visits for this solicitation to the Omaha
District will not be scheduled. Administrative and procedural questions
shall be directed to John M. Miller at (402) 221-4176. See Numbered
Note(s): 24. (0292) Loren Data Corp. http://www.ld.com (SYN# 0016 19951020\C-0003.SOL)
C - Architect and Engineering Services - Construction Index Page
|
|