COMMERCE BUSINESS DAILY ISSUE OF NOVEMBER 1,1995 PSA#1464CHIEF, A&MMS (90C), VA MEDICAL CENTER, 1055 CLERMONT STREET, DENVER, CO
80220 C -- A/E SERVICES - CORRECT FIRE SAFETY DEFICIENCIES SOL RFP 554-16-96
DUE 113095 POC Contracting Officer, Noella B. Pregill, (303)393-2849
This Project, Correct Fire Safety Deficiencies, Project No. 554-95-105,
consists of Mechanical and Electrical design work to upgrade the
facility's fire sprinkler system and smoke alarms. The work shall
include, but not limited to the following: 1. To provide CADD
deliverables of an up-to-date ''As-Built'' of all areas of the Medical
Center affected by the proposed new construction (to include
replacement of heads) on provided architectural CADD backgrounds. 100%
from hard copy drawings of the existing ''as-built'' system. 2. To
provide an Engineering Study of the existing and proposed Fire
Sprinkler Systems for determining the hydraulic capabilites of the
Station-wide Fire Protection System and a recommended plan of action
for future improvements, to include future hydraulic capabilities. The
study will include a detailed review/analysis. 3. Mechanical Design.
To replace existing Standard sprinkler heads with Quick Response
sprinkler heads at all locations on the 1st floor to the 9th floor (all
wings) for the main hospital, Buildings #24 and #38, and other areas as
may be required by code. To replace main shut off valve for Building B.
To add additional sprinklers at various locations of the facility, to
include hazardous areas, Library, X-ray areas, Pharmacy, Building #24,
high density shelving. Electrical Design. To add additional Smoke
Detection cabilities at various locations within the Medical Center.
This entire project shall be designed based upon the latest versions of
the NFPA codes and other codes, JACHO, RSFPE and other review agencies.
The A/E shall provide all professional services necesssary to perform
all required design services which will result in a complete set of
As-Built drawings of the existing fire protection sprinkler system, A
complete Hydraulic Study (review/analysis) A complete set of
Construction Drawings and Specification Documents for bidding purposes.
Construction period services, site investigation and a Fire Protection
Engineer's certification will also be required for this project. This
procurement is 100% set aside for Emerging Small Business, Standard
Industrial Code 8712. Qalified firms, within a 100 mile radius of
Denver, submitting applicable SF254/255 no later than close of business
11-30-95 will be considered. *NOTE: This is NOT a request for proposal.
(0303) Loren Data Corp. http://www.ld.com (SYN# 0025 19951031\C-0004.SOL)
C - Architect and Engineering Services - Construction Index Page
|
|