COMMERCE BUSINESS DAILY ISSUE OF NOVEMBER 3,1995 PSA#1466Contracting Officer (90C), DVA Medical Center, 3701 Loop Road East,
Tuscaloosa,, AL 35404 C -- A/E SERVICES SOL 679-108-96(BW) DUE 120695 POC Contracting
Officer, BARRY K. WILLIAMS, (205)933-4492 The DVAMC, Tuscaloosa,
Alabama requires the services of an A/E for the project titled ''TB
Modifications.'' The scope of work for this project is to prepare
preliminary plans and cost estimates for two concepts to meet HVAC
design criteria, i.e. exhausting all air and recirculating air with
mechanical controls. This will require material and installation cost
plus an energy evaluation. At the completion of the preliminary
submittal and approval of the disign concept, the A/E will proceed with
development of working drawings and specifications. Work will involve
but not limited to the following: modification to existing HVAC systems
in Ambulatory Care, Radiology and Morgue to meet Veterans Affairs HVAC
Design Criteria and CDC requirements. Design will require close
coordination with Engineering and Medical Center personnel, which will
involve detailed investigation and communications. The services of a
CIH will be required for the development of asbestos removal documents
and construction period monitoring/inspection. 2. The A/E shall
prepare all documents for this project from interaction and planning
with the DVA Engineering Service and Acquisition & Material Management
Service Staff. The A/E shall meet with the DVAMC staff as required to
accomplish the task described in the scope of work. The A/E shall make
site surveys, verify as-builts drawings, analyze existing utility
systems as necssary, and complete any and all work necessary to furnish
a complete Design Development in accordance with DVA Handbook H-08-15,
Volume C, ''Minimum Requirements for A/E Submissions for Minor and
Minor Miscellaneous projects and scope of the referenced project. The
construction costs for this project is estimated between $100,000 and
$500,000. The area of consideration is restricted to within a 250 mile
radius of the DVAMC, Tuscaloosa, Alabama. All interested firms should
submit the appropriate data (SF 254 and 255) as required by nubered
note #24 to the Contracting Officer at the address listed above by
CLOSE OF BUSINESS (4:30 PM LOCAL TIME) 12-6-95. THIS IS NOT A REQUEST
FOR PROPOSAL. SIC CODE 1542 applies. (0305) Loren Data Corp. http://www.ld.com (SYN# 0019 19951102\C-0006.SOL)
C - Architect and Engineering Services - Construction Index Page
|
|