COMMERCE BUSINESS DAILY ISSUE OF NOVEMBER 27,1995 PSA#1477Acquisition Branch C, OPM, Bldg. 13, Room G800, Bethesda, Maryland
20892-5711 Z -- TO PROVIDE SERVICES FOR VARIOUS MECHNICAL/ELECTRICAL UTILITY
RELATED TASK ORDERS RELATING TO A LARGE BOILER & REFRIGERATION T. SOL
263-96-P(CD)-0202 POC Milton Timmons, Contracting Officer,
(301)402-2163. The National Institutes of Health (NIH) seeks an A/E
contractor (SIC CODE 1872) to provide services for various
mechanical/electrical utility related task orders relating to a large
Boiler and Refrigeration Plant located at the NIH Campus, Bethesda,
Maryland. The A/E shall be responsible for developing designs and
construction documents for mechanical, electrical and structural
systems relating to the Boiler and Refrigeration Plants. The small
business size standard for SIC Code 1872 is $2.5 million. The NIH
Contracting Officer, Milton Timmons, is conducting a market survey to
determine the availability and potential technical capability of small
businesses to provide A/E services for various mechanical/electrical
utility relating to task orders. The existing boiler plant has a total
capacity of 800,000 lbs/hour steam which includes four (4) 150,000
lbs/hour boiler, that are over 40 years old, and one (1) new 200,000
lbs/hour boiler, along with the auxiliary equipment. The chiller plant
consists of two (2) buildings. The chiller plant has a total capacity
of 48,000 tons, which includes six (6) 5000 ton new chillers and six
(6) 3000 ton older chillers. Since this is a new procurement there is
not prior procurement history. The initial task order consists of the
preparation of a comprehensive system of Operation and Maintenance
Manuals. The Operation and Maintenance Manuals shall be a single source
reference manual containing complete information for start-up,
operation, maintenance, troubleshooting and programming both boiler and
refrigeration systems. The A/E firm shall be responsible for field
testing the manuals to verify correctness and usefulness. All work and
equipment required for field investigations and tests shall be
provided by the A/E firm. The A/E firm shall prepare all technical
drawings using CADD compatible with the Government CADD system. All of
the above work must be completed within 240 calendar days after
receiving the Notice to Proceed, and without interruption to normal
operation of the existing plants. Eligibility of the A/E firm for
completing work under thi contract shall be determined by the following
two (2) factors. In light of this project summary, interested
businesses are invited to submit tailored capability statements
addressing the factors below. Firms responding to this market survey
should keep in mind that only focused and pertinent information is
requested. 1. Past Performance on Similar Projects: The A/E firm shall
demonstrate successful completion of designs and the writing of O&M
manuals for large boiler and refrigeration plants having heating and
cooling application. The projects shall closely match in size and
complexity, with steam capacities equal or greater than 200,000 lbs/hr
and chilled water capacities equal or greater than 20,000 tons. The
A/E firm shall provide copies of previously completed O&M manuals for
at least two similar projects completed within the past five (5) years.
Copies of O&M manuals should demonstrate experience and technical
knowledge of steam and chilled water generation systems and associated
control technology. The documents should show that the A/E firm
possesses a clear understanding of standards and procedures for
start-up, operating, maintaining, testing, troubleshooting and
preventive maintenance of large plants. The A/E firm shall provide a
list of other designs completed, including references for the past
seven (7) years. References shall include the name of the installation,
with point of contact address and phone number. 2. Qualifications of
Key Personnel: Key personnel, as a minimum, shall include the
following: Project Manager: The Project Manager must be a registered
professional engineer with a Bachelor of Science degree in mechanical
engineering and the experience joined by being actively engaged in
power plant design, operation and maintenance for a least fifteen (15)
years. Experience must include a thorough knowledge of the electrical
and control technology application for large refrigeration and boiler
plants. This individual must possess a clear understanding of boiler
and refrigeration plant operation and must have at least seven (7)
years experience in preparing O&M manuals. Mechanical Project Engineer:
The Project Engineer must be an individual with a Bachelor of Science
degree in Mechanical Engineering. This degree may be substituted with
ten (10) years of experience in design, operation, and maintenance of
large boiler and refrigeration plants, or an individual with at
leasttwenty (20) years of experience operating and maintaining large
boiler and chiller plant operations. Electrical Project Engineer: The
Project Engineer must be an individual with a Bachelor of Science
degree in Electrical Engineering. This degree may be substituted with
ten (10) years of experience in electrical instrumentation and controls
relating to the design, operation, and maintenance of large boiler and
refrigeration plants, or an individual with at least twenty (20) years
of experience in providing instrumentation and control support to the
operation and maintenance of large boiler and chiller plant operations.
Technical Writer: The Technical Writer must have at least ten (10)
years of experience in writing and editing large complex technical
documents to include the development of O&M manuals. Civil/Structural
Project Engineer: The Project Engineer must be a registered
professional engineer with a Bachelor Degree in Civil Engineering and
a minimum of fifteen (15) years of experience in design and building
infrastructure utilities. This individual must have a thorough
knowledge of all building codes and state and local regulations.
(Experience cannot be considered a 100% substitute for education and
professional registration.) The key personnel shall be those who will
have the major project responsibilities. The availability of these
individuals is considered critical to the accomplishment of the
required services. These persons must be identified by name with
specific duties and responsibilities to be performed. A statement must
accompany the resumes of each person defining the extent of
availability and corporate commitment for the proposed position.
Responding firms should provide two (2) copies of a statement to the
above noted address within fifteen (15) business days from the date
this notice appears. This market survey is being conducted through the
CBD to reach the widest possible audience and to gather current market
information. A telfaxed response may be sent to the attention of Milton
Timmons fax number (301) 402-1103. powplant. (0326) Loren Data Corp. http://www.ld.com (SYN# 0163 19951124\Z-0047.SOL)
Z - Maintenance, Repair or Alteration of Real Property Index Page
|
|