|
COMMERCE BUSINESS DAILY ISSUE OF NOVEMBER 30,1995 PSA#1480Arnold Engineering Development Center, ATTN: AEDC PKP, 100 Kindel
Drive, Suite A332, Arnold AFB, TN 37389-1332 66 -- RECTILINEAR TRANSLATOR SYSTEM SOL F40650-96-R-0003 POC Alan C.
Fudge, Contracting Officer, (615)454-7841. USAF/AEDC intends to issue
a Request for Proposal (RFP) on a sole source basis to Mission
Reasearch Corp., Logan UT. The contract will procure two, 2-axis
rectilinear translator systems. The translators will be located inside
cryo/vacuum chamber and will be operated at room conditions as well as
under cryo/vacuum conditions at pressure levels down to 10 to the
negative 7 power torr and at tempertures down to 20 degrees K. The
maximum load for the translators will be 25 pounds and the speed will
be variable with a maximum of 3 inches per second. Thin film, molecular
bonded, drylubricant iis required for all load bearing
surfaces-conventional lubricants are not acceptable. The contractor
will provide the two translators, translator position transducers,
position readout electronics and will interface the translators to
existing AEDC translator drive electronics and will interface the
position readout electronics to an existing data acquisition and
control system. Considering a right-hand, rectangular Cartesian
coordinate system with the z-axis pointing up with respect to local
gravity, the first translator system will provide independent motions
in the x-axis and z-axis directions whereas the second translator
system will provide independent motions in the x-axis and y-axis
directions. For the first translator system, x-axis travel is 33 inches
while z-axis travel is 20 inches. For the second translator system, the
x-axis travel is 16 inches while the y-axis travel is 30 inches. For
both translators performance requirements are : position accuracy,
0.0001 inch; position resolution, 0.0001 inch; bi-directional position
repeatability, 0.0001 inch; straightness of travel, 0.00005 inch/inch;
flatness of travel, 0.00005 inch/inch; and axis-to-axis orthogonality
+-0.003 degrees. Conformance with performance and quality requirements
for the two translator systems will be demostrated at the contractor's
plant prior to acceptance by AEDC. Conformance with performance
requirements will be demostrated under room conditions as well as at
liquid nitrogen tempertures. Delivery of the translator systems is
expected within eight (8) months following contract awad. Firms
desiring to respond to this RFP must be certified and registered with
Defense Logistics Service Center (DLSC), Battle Creek, MI 49016-3412 to
acquire instructions for proposal preparation and contract performance.
Any persons desiring consideration must contact the AEDC Contracting
Officer listed above within fifteen (15) days after the publication
date of this synopsis and fully identify their interest and
capabilities. (0332) Loren Data Corp. http://www.ld.com (SYN# 0258 19951129\66-0002.SOL)
66 - Instruments and Laboratory Equipment Index Page
|
|