Arnold Engineering Development Center, ATTN: AEDC PKP, 100 Kindel Drive, Suite A332, Arnold AFB, TN 37389-1332

41 -- FILTER ELEMENTS AND HOLDERS SOL F40650-96-B-0014 DUE 022096 POC Kimberly M. Williams, Contract Specialist, (615)454-7841, W. Richard Stewart, Contracting Officer, (615)454-7841. This requirement is for the delivery and quality acceptance of filter elements with filter holders, 55 assemblies total, to remove 10 micron contaminents for the airstream. Fabricate the filter element holder from 304L stainless steel. The filter elements have a 10 inch inside diameter, 15.5 inch outside diameter, 28 inches long. A minimum surface area of 125 square feet is required per filter element. Media Conditions - Air: -120 degrees F to 650 degrees F. Flow Rate: 240,000 SCFM. (0361)

Loren Data Corp. http://www.ld.com (SYN# 0096 19951228\41-0009.SOL)