COMMERCE BUSINESS DAILY ISSUE OF JANUARY 23,1996 PSA#1515Kennedy Space Center, FL 32899 C -- REHABILITATE OR PROVIDE CIVIL/ENVIRONMENTAL SYSTEMS FOR
FACILITIES AT THE CAPE CANAVERAL AIR STATION (CCAS), VANDENBERG R FORCE
BASE(VAFB), SHUTTLE LANDING SITE, AND KSC, FLORIDA SOL R-129 POC
Vernetta Gary-Chavis, Contract Specialist, OP-ESO-A, 407-867-7230. 100
percent Small Business Set-Aside with subcontracting limitations in
accordance with FAR 52.219-14. SIC code 8711 with a size standard of
$20 million applies. This synopsis specifies the Government's
requirement, there is no separate solicitation package. No more than
one copy of the A&E's response to this notice is required. An A&E firm
will be selected to develop complete design packages and to provide
studies, surveys, reports, and at the discretion of KSC, to perform
other professional and incidental services for the subject project,
such as project and construction management support in all phases of
the work throughout the design and construction. This may include
review of shop drawings, resolution of problems, and the providing of
inspection services in the post design phase of the project. This
project shall include tasks which involve essential or substantial
effort in civil/environmental systems, equipment, and/or facilities.
The final designs, suitable for competitive bidding of NASA
requirements, will be associated with the restoration, rehabilitation,
or modification of existing facilities. The professional services
required for this project may include, but will not necessarily be
limited to, conducting field investigations, surveys, analysis of
existing and planned civil/environmental work and support systems, and
to prepare engineering reports of recommended action and/or design
packages. The selected A&E firm must have the capacity to provide all
the personnel to perform all the work identified. All packages prepared
by the A&E firm will include detail cost estimates. Approved designs
will be utilized for the advertising and award of fixed price
construction contracts. Project sites will be primarily located at KSC
and CCAS with minimal number located at other KSC support centers
including the VAFB. The selected A&E firm will provide services for
twelve (12) months and two additional one year options. All tasks will
require multi-disciplined engineering skills for performance of the
required work. The selected A&E firm's project staff must include, as
a minimum, specialists in the following engineering disciplines who
must have demonstrated experience in the specific disciplines:
Structural Engineer, Architect, Civil Engineer, Environmental Engineer,
Electrical Engineer, and Mechanical Engineer. This staff shall have a
combined experience in the design of sewage treatment facilities, road
repair and development, parking facilities, reconfigured and upgrade
of medium sized structures and facilities, site development including
storm water management and utilities, and facility and equipment design
to process and condition all types of hazardous and industrial waste
products. Additional demonstrated experience will be in industrial and
institutional type electrical systems, grounding, lighting, lightning
protection, fire alarm and detection systems, machine systems, and
construction management. The A&E shall also have demonstrated
experience in system testing, analysis and preparation of operating and
maintenance documentation, including spares provisioning as well as
failure and hazard analysis. The following evaluation factors are in
descending order of importance and will be used in the evaluation of
all A&E submittals for this project. NASA will consider the immediate
past 10 years as the period of time for evaluation under factors (1)
and (2). 1. Specialized experience and technical competence in the type
of work required.(selection weight, 35 percent) 2. Past performance on
contracts with Government agencies and private industry in terms of
cost control, quality of work, compliance with performance schedules,
and success in prescribing the use of recovered materials and achieving
waste reduction and energy efficiency in facility design.(selection
weight, 25 percent) 3. Professional qualifications necessary for
satisfactory performance of required services.(selection weight, 15
percent) 4. Capacity to accomplish the work in the required
time.(selection weight, 10 percent) 5. Location of the essential staff
for this project (or a commitment to locate) in the general
geographical area of the project and knowledge of the locality of the
project, provided that application of this criterion leaves an
appropriate number of qualified firms, given the nature and size of the
project. (selection weight, 10 percent) 6. Volume of work (A&E Fees)
previously awarded to the firm by NASA during the last ten years with
the object of effecting an equitable distribution of contracts among
qualified architect and engineer firms, including minority- owned firms
and firms that have not had prior NASA contracts.(selection weight, 5
percent) As a part of your submittal, provide in order of the above
factors, a specific response to each factor. Specify A&E Fees, if any,
received by prime contract with NASA. A&E's responding to this notice
should submit, along with the Standard Forms 254 and 255, any
additional information that they deem to be of benefit to their firm in
the selection process. The proposed design team qualifications as they
relate to the specialized experience and technical competence required
for this project should be stated.. Closing date for responding to this
notice is close of business 2/20/96. Offerors are cautioned that
submittals received after the specified closing date may be considered
late---see note 24---all references in numbered Note 24 to the
Department of Defense shall be changed to read National Aeronautics and
Space Administration. Technical questions should be directed to Mr. R.
A. Armstrong, Mail Code, DF-FSO, telephone 407 -867-7517. Submittals
should be made in writing to NASA, John F. Kennedy Space Center, Mail
Code: OP-ESO-A, Headquarters Building M6-399, Attn: Vernetta G. Chavis,
Room 2484, Kennedy Space Center, FL 32899. Please reference R-129 when
responding. See Numbered Note(s) 1 and 24. (0019) Loren Data Corp. http://www.ld.com (SYN# 0015 19960122\C-0004.SOL)
C - Architect and Engineering Services - Construction Index Page
|
|