|
COMMERCE BUSINESS DAILY ISSUE OF JANUARY 31,1996 PSA#1521Universities Research Association, Inc/Fermi National Accelerator
Laboratory, PO Box 500, Batavia, IL 60510-0500 H -- QUALITY CONTROL, TESTING AND INSPECTION SERVICES SOL
FESS-6895-RCH. Due 032096. Contact Robert C Huite, Senior Contract
Administrator, 708/840-3387. Quality control, testing and inspection
services, Universities Research Association, Inc/Fermi National
Accelerator Laboratory (Fermilab) request expressions of interest for
request for proposal to provide Geotechnical Engineering and Testing
Services. The subcontract resulting from this request for proposal will
be for a base period of one year with two two-year option periods.
Subcontractor shall furnish all management, supervision, personnel,
material, supplies and equipment (except as otherwise provided) and
shall plan, schedule, coordinate and assure effective performance of
all services. The Subcontractor shall provide professional Geotechnical
Engineering and Testing Services. Work scope includes, but is not
necessarily limited to, soil and rock boring, soil and rock material
testing and analysis, providing engineering recommendations and design
parameters, weld and bolt testing and inspection, concrete testing,
insitu and cylinders; building envelope and structural frame inspection
and testing; and digging where profiles are known. The subcontractor
shall be responsible for furnishing the various professional and
technical classifications and the kinds of equipment required, as well
as any other equipment, tooling, material and supplies, directed by
Fermilab. All work performed by the subcontractor shall be in the form
of a Task Order issued by Fermilab for all labor, equipment,
materials, and supplies, as required, and shall be in accordance with
Fermilab's authorizations and directions set forth in the Task Order.
The Subcontractor shall be responsible to assure that the quality of
workmanship and material provided under this Subcontract meets normal
industry standards. Defective and/or unsatisfactory workmanship caused
by untrained and/or careless tradesmen or work accomplished contrary
to plans and specifications shall be replaced at the subcontractor's
expense. Unless otherwise specified by the subcontractor, the on-site
supervisor shall be assumed to be responsible for Quality Assurance.
Firms responding to this announcement shall be required to be located
within seventy-five (75) miles of Batavia, Illinois; have a minimum of
ten (10) years in the Geotechnical Engineering and Testing Services;
and have a minimum of five (5) drilling rigs at time of subcontract
award. (026) Loren Data Corp. http://www.ld.com (SYN# 0025 19960130\H-0001.SOL)
H - Quality Control, Testing and Inspection Services Index Page
|
|