COMMERCE BUSINESS DAILY ISSUE OF FEBRUARY 1,1996 PSA#1522Room 6875, JEH-FBI Bldg., 10th & Pennsylvania Ave., NW, Washington DC
20535 66 -- GYRO-STABILIZED IMAGE BINOCULARS SOL 6930 POC Richard I.
Sanders, Contract Specialist, 202/324-2279. The Federal Bureau of
Investigation (FBI) has a requirement for an Indefinite
Delivery-Requirements type contract for the acquisition of two models
of Gyro-Stabilized Binoculars (GSB). The FBI intends to issue a
solicitation that will be evaluated on the basis of the best value to
the Government per line item. The specifications of the GSB 12x and 16x
magnifying power should include but are not limited to the following:
Optical characteristics- The GSB 12x unit shall have fixed magnifying
power of 12.0 plus or minus 3% in each of its individual telescope and
the GSB 16x unit shall have fixed magnifying power of 16.0 plus or
minus 3% in each of its individual telescope; The minimum differential
in each unit shall not exceed 2%; The minimum objective lens diameter
of each GSB unit is 40 millimeters (mm); The minimum field of view of
the 12x unit shall be 4.5 degrees and 3.4 degrees for the 16x unit;
Each GSB unit shall have individual eyepiece focusing; The minimum
diopter range of each GSB unit shall be plus or minus 4; The minimum
eye relief of the GSB 12x unit shall be 16.0 mm and for the 16x unit it
shall be 12.0mm; The on-axis, high contrast (100 percent) resolution of
the 12x GSB unit shall not be greater than 10.30 arc seconds per
line-pair with no vibration input and the 16x unit shall not be greater
than 7.7 arc seconds per line-pair with no vibration input.
Stabilization Characteristics- Stabilization of the optical image shall
be achieved for each unit by internal stabilization of the optics. The
stabilization system shall be capable of removing image motion in
pitch and yaw smoothly increasing fashion; The minimum stabilization
freedom of each GSB unit shall not be 5.0 degrees. The scanning rate of
each GSB unit shall not be less than 5.0 degrees/second; The maximum
external dimensions of each GSB unit shall be 220 mm x 220m x 100 mm;
The maximum weight of each GSB unit shall not exceed 2.0 plus or minus
0.15 kilograms; Each GSB unit shall have interpupillary adjustment
range from 60mm to 70mm. Electrical Characteristics- Each GSB unit
shall be capable of operating on either standard ''AA'' commercial
batteries internally or on an external power supply; Each GSB unit
shall be capable of operating 12 to 28 volts DC; Each GSB unit shall
have at least two control switches, one ON/OFF and another CAGE/UNCAGE
control switch. Further specifications and estimated quantities will
be provided upon request for RFP-6930. A bid sample(s) is required.
Offerors will have 90 days after the receipt of solicitation package to
produce a bid sample. Unsuccesful bid samples will be returned upon
award of contract. Bid offers must be submitted during the same period
of time. Request for RFP-6930 must be in writing and postmarked no
later than fifteen (15) calendar days from date of this notice. Any
request postmarked after 15 days will be subject to the availability of
soliciatation packages. All inquiries must be made in writing. (0030) Loren Data Corp. http://www.ld.com (SYN# 0386 19960131\66-0002.SOL)
66 - Instruments and Laboratory Equipment Index Page
|
|