COMMERCE BUSINESS DAILY ISSUE OF FEBRUARY 22,1996 PSA#1536US Army ARDEC, AMSTA-AR-PCM-G, Bldg 9, Picatinny Arsenal, New Jersey
07806-5000 J -- POWER PLANT BOILERS AND AUXILIARY CONTROLS, GAS TRAIN AND RELATED
EQUIPMENT, INSTRUMENTATION SOL DAAE30-R-1017 DUE 030796 POC Theresa
Niederhaus email=tneider, 201-724-3362; Contracting Officer, John H.
Beeman. To provide service to furnish all labor, travel, testing,
testing equipment parts and materials to inspect, calibrate, and repair
boiler controls, boiler auxliary regulators, controllers, recorders and
equipment instrumentations at Bldg.'s 506 and 3013 for the following
equipment: Boiler no. 3 is located at bldg. 3013, made by Bigelow
Boiler Co., rated at 50,000 lbs/hr, saturated steam water tube boiler
using no. 2 fuel oil with the following: Burner Management System,
Fireye Flame Monitor Control EP160, Feedwater Regulator, by Leslie,
Size 2, Class DD06, Serial No. 7314782 with level matic pilot
Controller, Type LAP SN 723-923-2, Auxiliary deaerator with make up
water regulator and deaerator pressure regulator; Boiler no. 4, located
at bldg. 506, made by Riley Stoker, rated at 50,000 lbs/hr, superheated
steam at 430 psig, water tube boiler, capable of using no. 6 fuel oil
and natural gas with the following: Oxygen Analyzer, Fuel Oil Control
Valve, Atomizing Steam Control Valve, Feedwater Regulator, Smoke
Indicator by Combustion Control Division Fireye type 27VH6, Single Loop
Digital Controller, Micro 352 by Moore Product Co.: Boiler numbers 5
and 6, identical 4 drum water tube boilers, manufactured by Combustion
Engineering, are located at bldg. 506. Each boiler is rated at 160,000
lbs/hr, superheated steam at 430 psig capable of using no. 6 fuel oil
and natural gas with the following (for each boiler): Feedwater
Regulator by Bailey Meter Co., Valve Size 40, type VBA-152X, Style
6060F, SN H82386 with Bailey I/P Electro-Pneumatic Positioner, Fuel Oil
Control Valve by Fisher Governor Co., Size 2, SN 2572235, Type 507 with
I/P Electro Pneumatic Positioner, Smoke Indicator, by Electronic Corp.
of America, Fireye, Type 27VH6, Model 1000, Three Electronic
Recorders, by Foxboro Co., Model ESAZIAN for Drum level and Feedwater
Flow, Steam Flow and Air Flow, and Plant Steam Pressure, Actuator
Positioner, Electro Pneumatic by Bailey Co. SN 004420.01, Air Servo
Cylinder Model: LFCOCH01B Air Servo Valve, one Actuator Position for
each boiler Forced Draft Fan Inlet damper and Inducted Draft Fan Gyrol
Fluid Drive Speed Changer: Single Loop Digital Controller, MICRO 352
by Moore Products Company. There is one controller for each boiler
furnace pressure control, combustion air flow control, feedwater
flow/drum level control, fuel oil valve/firing control and plant water
steam pressure control: Leeds and Northrop Speedomax Temperature
Recorder: Bldg. 506 Auxiliaries include: Make up steam 60 and 125 psig
steam pressure regulators, including desuperheater, Deaerators water
level and steam pressure regulators, Superheaters 430 psig, 430/60, 60
and 125 psig supply line temperature regulators, Closed Feedwater
heaters level controllers, Condenser condensate level controllers: Gas
Train and related equipment: The work consists of furnishing all
labor, travel, testing testing equipment parts and materials to perform
maintenance, repair and reconditioning, including resetting of valves
and gages, regulators, purging of natural gas carrying pipelines from
outside of the metering cage up to, and including, the gas burner for
boiler numbers 4, 5, and 6 located in bldg. 506. Currently boiler
numbers 4, 5 and 6 are operable on gas/oil dual fuel capability. The
government intends to operate boilers on gas during the heating season
to supply the major portion of steam on the installation. The
contractor, upon receiving a service call, shall have sufficient
material/supplies and equipment available to complete the maintenance
and repair work in a manner which results in minimum downtime for the
boilers. Period of performance for one year from date of award with two
years option to renew. Information regarding this action can be
accessed at http://procnet.pica. See Numbered Note(s): 1. (0051) Loren Data Corp. http://www.ld.com (SYN# 0055 19960221\J-0001.SOL)