COMMERCE BUSINESS DAILY ISSUE OF MARCH 11,1996 PSA#1548Rhonda P. Mullendore, Code 092S, Indian Head Division, Naval Surface
Warfare Center, Building 551, Indian Head, Maryland 20640-5035 C -- MISCELLANEOUS CIVIL/STRUCTURAL DESIGN AND ENGINEERING SERVICES
(INDEFINITE QUANTITY CONTRACT), INDIAN HEAD DIVISION, NAVAL SURFACE
WARFARE CENTER, INDIAN HEAD, MARYLAND SOL N62477-96-D-3546 DUE 040296.
Contact Point, Rhonda P. Mullendore, 301/743-4402, Sheila K.
Lundstrom, Contracting Officer, 301/743-4402. The work includes an
indefinite quantity contract for civil and structural design and
engineering services with multi-disciplinary support. Delivery
orders/projects may include but not be limited to: preparation of
studies, technical report and conceptual designs, conducting
engineering evaluations and preparation of construction contract
drawings, specifications, engineering calculations and cost estimates,
complete and ready for bidding. The A/E firm may also have to provide
Post Construction Award Services such as as-built drawing preparation,
review and approval of shop drawings, construction site visits and
consultation during construction. Although none is now known, the
possibility of hazardous materials, i.e. asbestos and lead paint, may
exist at the project sites. If hazardous materials are encountered, the
A/E Contractor may be required to conduct testing and sampling, as well
as provide design removal procedures in accordance with applicable
rules and regulations. Potential civil/structural engineering projects
include but may not be limited to: structural repairs to building,
utility repair and replacement, roof repair and replacement, bituminous
paving, repairs to water-front facilities, site improvements, lead
abatement, secondary containment for tanks and process piping and
waste-water treatment. The preparation of comprehensive storm water
management plans or waivers for the State of Maryland may also be
required under this contract. The duration of this contract will be for
a period of one year. The Government reserves the right to exercise up
to one additional year for additional services based on funding
availability and satisfactory performance by the Contractor during the
initial contract period. Individual fees for any one project will not
exceed $99,000.00. The total fees per year shall not exceed
$200,000.00. Individual fees for any one project will not exceed
$99,000.00. The total fees per year shall not exceed $200,000.00.
Individual fees for any one project will not exceed $99,000. Selection
evaluation criteria, in relative order of importance, include: (1)
Specialized experience and professional qualifications of the firm (and
its subcontractors) in the following areas: a. Design of structural
renovations to industrial-type buildings including roof repair and
replacement, equipment foundations and conductive flooring. b. Design
of utility related projects including above-ground steam lines, potable
water, sewer, storm drain and fire protection systems. c. Design of
projects mentioned above with application with application of the
NAVSEA OP-5 manual. d. Design of bituminous roadway and repairs. (2)
Demonstrate the capabilities in the following areas: a. Ability to
sustain the loss of key personnel while completing the work within the
required time limits. b. Coordinating and repairing all required
permits for the State of Maryland especially storm water management
waivers requests. (3) Location - Firms will be evaluated on their
location with respect to the general geographical area of the contract
and their knowledge of local codes, laws, permits, climate,
construction materials and practices of the area (provided that the
application of this criterion leaves and appropriate number of
qualified firms, given the nature and size of the project); (4) Provide
information regarding the firm's past performance in providing an
internal quality control program to assure technically accurate plans,
specifications, and construction cost estimates, Indicate the
effectiveness of this program in providing the following specific data:
a. track record for providing project submission within established
design-to amounts; b. track record for providing project submissions
within established performance schedules. Please provide a reference
for each project listed, including their phone number. (5) Provide
information regarding the firms current status: a. Present firm's
workload in respect to the project team availability, including
subcontractors. (6) Preference will be given to firms with the
capability of using CAD, SPECSINTACT, and the Cost Estimating Systems.
Firms are required to prepare cost estimates utilizing a computerized
format and the specifications in the SPECSINTACT system format. Firms
shall be responsible for accomplishing designs and preparing drawings
utilizing Computer-Aided Design and Drafting (CADD) and delivering the
drawings in Intergraph MicroStation PC, version 5 or higher, MD-DOS,
digital format (.dgn). The Government will only accept the final
product for full operation, without conversion or reforming on the
target system. The current target system is MS-DOS/WINDOWS operating
system. Scanned drawings shall be delivered in native Intergraph
format. Each firm's past performance(s) and performance ratings will be
reviewed during the evaluation process and can effect the selection
outcome. Architect-Engineer firms which meet the requirements described
in this announcement are invited to submit a completed SF254 (unless
already on file) and SF 255, U.S. Government Architect-Engineer
Qualifications to the office shown below. Firms responding by close of
business (3:00 P.M.) on the thirtieth (30th) day from this
announcement will be considered and firms having a current SF 254 on
file with this office can be considered. Site visits will not be
arranged during the advertisement period. This proposed contract is
being solicited on an unrestricted basis. Small Business size standard
SIC Code is ``8711,'' $2.5 million averages over a three year period.
Interested firms are requested to include telefax numbers, the
Contractor Establishment Code (CEC), and Taxpayer Identification Number
(TIN) on the SF 255 and SF 254 in Blocks 3a and 1, respectively. In
Block 10, state why your firm is specially qualified based on the
selection evaluation criteria. Also, use Block 10 to provide additional
information desired by your firm. Only the SF 254 and 255 will be
reviewed. Experiences identified in Block 8 should not be more than 5
years old. The A/E firm's primary person proposed to be the direct
contact with the Indian Head Division NAVSURFWARCEN through the
contract work should be identified as the ``Project Manager.''
Information in the cover letter and any other attachments will not be
included in the official selection process. Fax copies of the SF 254
and 255 will not be accepted. This is not a request for proposal. No
other general notification to firms under consideration will be made
and no further action is required. Contracting Officer, Indian Head
Division, Naval Surface Warfare Center, Code 092B, Building 551, 101
Strauss Avenue, Indian Head Maryland 20640-5035. See Note 24. (064) Loren Data Corp. http://www.ld.com (SYN# 0043 19960308\C-0010.SOL)
C - Architect and Engineering Services - Construction Index Page
|
|