COMMERCE BUSINESS DAILY ISSUE OF MARCH 13,1996 PSA#1550NIH, National Heart, Lung, and Blood Institute, COB, Procurement
Section, 6701 Rockledge Drive MSC 7902, Bethesda, MD 20892-7902 66 -- HIGH RESOLUTION LIQUID CHROMATOGRAPH SOL NHLBI-PS-SP-96-202 POC
Cecilia Morales, Purchasing Agent, Debra Hawkins, Contracting Officer,
(301) 435-0366. The National Heart, Lung, and Blood Institute (NHLBI)
intends to purchase a High Resolution Liquid Chromatograph System with
the following components: one (1) Magic 202 Micro/Anal HPLC unit, two
(2) Magic Microbore Pumpheads, one (1) Magic 50ul Mixer Cartridge, one
(1) Magic Micro Flowcell Assembly one (1) Magic Win95 System
Controller, installation and training. The system must meet the
following minimum specification: 1) Gradient Flowrates with Analytical
0.1-5.0ml/min Splitless), Microbore 20 - 1000 ul/min (Splitless),
Capillary 0.5-25ul/min (Splitflow); 2) Pressure Range with 0 - 5000 PSI
(Splitflow or Splitless); 3) Solvent Capacity with 100-1000ml
Reservoirs (Solvents A, B and Wash); 4) pH Range with 2-10; 5) Dual
Stage Mixers with 3ul Static Vortex Block Plus Variable Volume
Cartridges (50, 100, 200, 500 and 1000 ul); 6) Temperature Control with
Forced Air Oven Ambient to 60C; 7) Sample Injection with 10 Port Valve
- Manual or Autoinject 0.1-1000ul Volume (Loop or Trap); 8) Column
Compatibility with Conventional (2 x 20mm to 10 x 250mm), Michrom
Custom (0.3 x 50mm to 2 x 150mm), Packed Capillary (50u x 50mm to 300u
x 250 mm); 9) Detection with Single or Dual Wavelength Modes (w/Peak
Scan) 190 -700 nm (Simultaneous D2 and W Lamps): 10) Flowcells with
Analytical 2.4 ul / 5 mm path, Microbore 0.3 ul / 2 mm path, Capillary
20 nl / 0.1 mm path; 11) System Control with Windows 95 (or NT) Full
Digital Control including Realtime, Methods Development and Diagnostics
Interlaces with Michrom Windows 95 Data System interfaces to many HPLC
and MS Data Systems: 12) Physical dimension: 19''W x 26''H x 23''D;
13) Power Requirements: 47-63Hz, 100-240 VAC, 600 Voltamps: 14) Gas
Requirements: 60-200 PSI Helium input. Responses to this noitce must
submit clear and convincing technical documentation, indicating the the
items being proposes meets the government's minimum specifications. The
Request for Quotation (RFQ) Number NHLBI-PS-SP-96-202, will be due 15
calendar days after the publication date of this synopsis. The
anticipated award date of the purchase order is 4/1/96. All Interested
sources may submit a quotation which if timely received, shall be
considered by the agency. Requests for copies of the RFQ must be in
writing and may be requested by FAX to (301) 480-3345. Oral quotations
will not be accepted. Written quotations must be submitted to the
National Heart, Lung, and Blood, Institute, Contracts Operations
Branch, Procurement Section, Building RKL2, Room 6143, 6701 Rockledge
Drive, Bethesda, MD 20892-7902, Attention: Ms. Cecilia Morales. FAX
quotations will only be accepted if dated an signed by an authorized
company representative. (0071) Loren Data Corp. http://www.ld.com (SYN# 0412 19960312\66-0001.SOL)