COMMERCE BUSINESS DAILY ISSUE OF APRIL 1,1996 PSA#1563Commander, U.S. Army Missile Command, Acquisition Center, Redstone
Arsenal, AL 35898-5280 66 -- DIAPHRAGM CAPACITANCE GAUGE W/DIRECT PRESSURE DIGITAL READOUT
(DCG/DPDR) (0.0001-1.0000); (0.01-100.00); (0.001-10.000);
(0.1-1000.0); (0.01-100.0) SOL DAAH01-96-T-0585 DUE 052096 POC Lana P.
Decker, Contract Specialist, AMSMI-AC-CFFA, (205) 842-7331, Gary
Poolos, Contracting Officer, AMSMI-AC-CFFA, (205) 876-4153, PCF.
Synopsis Number 0152-96. (i) This is a combined synopsis/solicitation
for commercial items prepared in accordance with the format in subpart
12.6, as supplemented with additional information included in this
notice. (ii) The solicitation number DAAH01-96-T-0585 is hereby issued
as a Request for Quotation (RFQ). (iii) The solicitation document and
incorporated provisions and clauses are those in effect through
Federal Acquisition Circular 90-32. (iv) This acquisition is
unrestricted. (v) All items shall be delivered within 90 days after
contract award. Earlier delivery is acceptable and desirable at no
additional cost to the Government. Deliveries shall be made F.O.B.
Destination to Redstone Arsenal Support Activity, Installation Supply
Activity Account, Bldg. 8022, Redstone Arsenal, AL 35898-5330.
Inspection and acceptance shall be at destination. (vi) FAR 52.212-1,
Instructions to Offerors-Commercial Items is applicable. (vii) FAR
52.212-2, Evaluation - Commercial Items is applicable. (viii) The
offeror shall include a complete copy of the FAR provisions at
52.212-3, Offeror Representations and Certifications - Commercial
Items. (ix) FAR 52.212-4, Contract Terms and Conditions - Commercial
Items is applicable. The Government intends to award a contract
resulting from this solicitation to the responsible, responsive,
technically acceptable, and lowest priced offeror whose offer conforms
to the solicitation and will be most advantageous to the Government.
(x) FAR 52.212-5, Contract Terms and Conditions Required to Implement
Statutes or Executive Orders - Commercial Items is applicable. (xi) An
evaluation shall be performed to determine if each quote is
technically acceptable. A technically acceptable quote must clearly
show that the offeror can meet the minimum requirements of the
Government. Each quote will be reviewed to assure that each function
included in the specification is addressed in the quote. Therefore,
each offeror must respond to each functional requirement of the
specification. (xii) Bar code marking is not required. (xiii) Offers
are due 20 May 1996, 2:00 p.m. local time. The proposal must be signed
by an official authorized to bind your organization. You must submit
two (2) copies to: U.S. Army Missile Command, AMSMI-AC-CFFA/Ms. Lana P.
Decker, Redstone Arsenal, AL 35898-5280, Solicitation Number
DAAH01-96-T-0585. Offers may be submitted on letterhead stationary and,
at a minimum, must show: (1) the solicitation number; (2) the time
specified in the solicitation for the receipt of offers; (3) the name,
address, and telephone number of the offeror; (4) a technical
description of the items being offered in sufficient detail to evaluate
compliance with the requirements of the solicitation. This may include
product literature, or other documents, if necessary; (5) terms of any
express warranty; (6) price and discount terms; (7) ''remit to''
address, if different from mailing address; (8) a completed copy of the
representations and certifications; (9) if the offer is not submitted
on the SF 1449, include a statement specifying the extent of agreement
with all terms, conditions, and provisions included in the
solicitation. Offers that fail to furnish required representation or
information, or reject the terms and conditions of the solicitation may
be excluded from consideration. Information regarding this solicitation
can be obtained from Ms. Lana Decker, (205) 842-7331. (xiv) DESCRIPTION
OF REQUIREMENTS FOR THE ITEMS TO BE ACQUIRED: DIAPHRAGM CAPACITANCE
GAUGE WITH DIRECT PRESSURE DIGITAL READOUT. NOMENCLATURE: Absolute
Pressure Capacitance Manometer QUANTITY: 1 PRESSURE RANGE:
0.0001-1.0000 torr absolute OVERPRESSURE RATING: 120% full scale
ACCURACY: to hold +/- 0.05% of reading across entire pressure range for
a one year interval FITTINGS: CAJON 4 VCR-female OUTPUT: 0-10 VDC
OPERATING TEMPERATURE: 15 to 40 Degrees Celsius (gauge will have
internal heater regulated to +/- 1 degrees Celsius) MEDIA
COMPATABILITY: Air, Nitrogen REFRENCE PRESSURE: Refrence side of
diaphragm maintained at 1E-7 torr or better DIGITAL READOUT: 5 1/2
Digit LCD RANGE SELECTIONS ON READOUT: X1, X.1, X.01 of Full Scale
READOUT ACCURACY: .001% full scale READOUT PRESSURE UNITS: mmHg, Kpa,
Inche Hg, Inches Water, psi OPERATING TEMPERATURE (READOUT): 15 to 40
Degrees Celsius ELECTRONIC ZERO ON FRONT PANEL OF READOUT READOUT POWER
REQUIREMENTS: 115-120 VAC, 60 HZ CABLES: If cable hookup between gauge
and readout is required, a cable with minimum length of 6 feet is
required. DIAPHRAGM CAPACITANCE GAUGE WITH DIRECT PRESSURE DIGITAL
READOUT NOMENCLATURE: Absolute Pressure Capacitance Manometer QUANTITY:
1 PRESSURE RANGE: 0.01-100.00 torr absolute OVERPRESSURE RATING: 120%
full scale ACCURACY: to hold +/- 0.05% of reading across entire
pressure range for a one year interval FITTINGS: CAJON 4 VCR-female
OUTPUT: 0-10 VDC OPERATING TEMPERATURE: 15 to 40 Degrees Celsius (gauge
will have internal heater regulated to +/- 1 degrees Celsius) MEDIA
COMPATABILITY: Air, Nitrogen REFRENCE PRESSURE: Refrence side of
diaphragm maintained at 1E-7 torr or better DIGITAL READOUT: 5 1/2
Digit LCD RANGE SELECTIONS ON READOUT: X1, X.1, X.01 of Full Scale
READOUT ACCURACY: .001% full scale READOUT PRESSURE UNITS: mmHg, Kpa,
Inche Hg, Inches Water, psi OPERATING TEMPERATURE (READOUT): 15 to 40
Degrees Celsius ELECTRONIC ZERO ON FRONT PANEL OF READOUT READOUT POWER
REQUIREMENT: 115-120 VAC, 60 HZ CABLES: If cable hookup between gauge
and readout is required, a cable with a minimum length of 6 feet is
required. DIAPHRAGM CAPACITANCE GAUGE WITH DIRECT PRESSURE DIGITAL
READOUT NOMENCLATURE: Absolute Pressure Capacitance Manometer QUANTITY:
1 PRESSURE RANGE: 0.001-10.000 torr absolute OVERPRESSURE RATING: 120%
full scale ACCURACY: to hold +/- 0.05% of reading across entire
pressure range for a one year interval FITTINGS: CAJON 4 VCR-female
OUTPUT: 0-10 VCD OPERATING TEMPERATURE: 15 to 40 Degrees Celsius (gauge
will have internal heater regulated to +/- 1 degrees Celsius) MEDIA
COMPATIBILITY: Air, Nitrogen REFRENCE PRESSURE: Refrence side of
diaphragm maintained at 1E-7 torr or better DIGITAL READOUT: 5 1/2
Digit LCD RANGE SELECTIONS ON READOUT: X1, X.1, X.01 of full scale
READOUT ACCURACY: .001% full scale READOUT PRESSURE UNITS: mmHg, Kpa,
Inche Hg, Inches Water, psi OPERATING TEMPERATURE (READOUT): 15 to 40
Degrees Celsius ELECTRONIC ZERO ON FRONT PANEL OF READOUT READOUT POWER
REQUIREMENT: 115-120 VAC, 60 HZ CABLES: If cable hookup between gauge
and readout is required, a cable with a minimum length of 6 feet is
required. DIAPHRAGM CAPACITANCE GAUGE WITH DIRECT PRESSURE DIGITAL
READOUT NOMENCLATURE: Absolute Pressure Capacitance Manometer QUANTITY:
1 PRESSURE RANGE: 0.1-1000.0 torr absolute OVERPRESSURE RATING: 120%
full scale ACCURACY: to hold +/- 0.05% of reading across entire
pressure range for a one year interval FITTINGS: CAJON 4 VCR-female
OUTPUT: 0-10 VDC OPERATING TEMPERATURE: 15 to 40 Degrees Celsius (gauge
will have internal heater regulated to +/- 1 degrees Celsius) MEDIA
COMPATABILITY: Air, Nitrogen REFRENCE PRESSURE: Refrence side of
diaphragm maintained at 1E-7 torr or better DIGITAL READOUT: 5 1/2
Digit LCD RANGE SELECTIONS ON READOUT: X1, X.1, X.01 of Full Scale
READOUT ACCURACY: .001% full scale READOUT PRESSURE UNITS: mmHg, Kpa,
Inche Hg, Inches Water, psi OPERATING TEMPERATURE (READOUT): 15 to 40
Degrees Celsius ELECTRONIC ZERO ON FRONT PANEL OF READOUT READOUT POWER
REQUIREMENT: 115-120 VAC, 60 HZ CABLES: If cable hookup between gauge
and readout is required, a cable with a minimum length of 6 feet is
required. DIAPHRAGM CAPACITANCE GAUGE WITH DIRECT PRESSURE DIGITAL
READOUT NOMENCLATURE: Differential Pressure Capacitance Manometer
QUANTITY: 1 PRESSURE RANGE: 0.01-100.00 torr differential OVERPRESSURE
RATING: 120% full scale ACCURACY: to hold +/- 0.05% of reading across
entire pressure range for a one year interval FITTINGS: CAJON 4
VCR-female OUTPUT: 0-10 VDC OPERATING TEMPERATURE: 15 to 40 Degrees
Celsius (gauge will have internal heater regulated to +/- 1 degrees
Celsius) MEDIA COMPATABILITY: Air, Nitrogen REFRENCE PRESSURE: Refrence
side of diaphragm maintained at 1E-7 torr or better DIGITAL READOUT: 5
1/2 Digit LCD RANGE SELECTIONS ON READOUT: X1, X.1, X.01 of Full Scale
READOUT ACCURACY: .001% full scale READOUT PRESSURE UNITS: mmHg, Kpa,
Inche Hg, Inches Water, psi OPERATING TEMPERATURE (READOUT): 15 to 40
Degrees Celsius ELECTRONIC ZERO ON FRONT PANEL OF READOUT READOUT POWER
REQUIREMENT: 115-120 VAC, 60 HZ CABLES: If cable hookup between gauge
and readout is required, a cable with a minimum length of 6 feet is
required. (0088) Loren Data Corp. http://www.ld.com (SYN# 0263 19960329\66-0001.SOL)