COMMERCE BUSINESS DAILY ISSUE OF APRIL 12,1996 PSA#1572NASA, George C. Marshall Space Flight Center, Procurement Office,
Marshall Space Flight Center, AL 35812 66 -- TEST MACHINE INSTRUMENTATION SOL 8-P-6-21-B2294 POC Contact
GP22C/Teresa A. Foley/Contracting Officer, 205-544-0335 NASA/MSFC plans
to issue a Request for Quotation (RFQ) for Test Machine Instrumentation
-- NASA/MSFC intends to purchase from MTS Systems Corporation the
following: Item 1 - Extensometer, MTS Systems Model No. 632.11E-21 --
Quantity 1 ea-- Item 2 - Extensometer, MTS Systems Model No. 632.12E-21
-- Quantity 1 ea -- Item 3 - Bi Axial Extensometer, MTS Systems Model
No. 632.80, 2.0 inch gage length--Quantity 1 ea -- Item 4 - Two ranges
of calibration for Item 3--Quantity 1 ea--The following specifications
are provided: Item 1 - The extensometer gage length shall be 1.000 inch
+/- 0.002 inch and the travel shall be +/- 0.150 inch--The operational
temperature range of the extensometer shall be -450F to +150 F--The
extensometer linearity shall not exceed 0.15% with a hysteresis not to
exceed 0.10%--The activation force shall not exceed 45 grams and the
over all extensometer weight shall not exceed 26 grams--The
extensometer shall interface directly to a MTS test star digital
control system and shall have the appropriate electrical
connectors--The extensometer shall be supplied with a spare set of
standard knife edges, a spring attachment kit, a certificate of
linearity and gage factor and an instruction manual with connectivity
documentation-- Item 2 - The extensometer gage length shall be 1.000
inch + 0.002 inch and the travel shall be + 0.500 inches - 0.100
inch--The operational temperature range of the extensometer shall be
-450 degrees F to +150 degrees F--The extensometer linearity shall not
exceed 0.30% with a hysteresis not to exceed 0.10%--The activation
force shall not exceed 45 grams and the over all extensometer weight
shall not exceed 30 grams--The extensometer shall interface directly to
a MTS test star digital control system and shall have the appropriate
electrical connectors--The extensometer shall be supplied with a spare
set of standard knife edges, a spring attachment kit, a certificate of
linearity and gage factor and an instruction manual with connectivity
documentation--Items 3 and 4 - The extensometer axial gage length shall
be 2.000 inch + 0.002 inch and the travel shall be + 0.040 inch - 0.020
inch-- The extensometer shall accommodate specimens up to 0.5 inches in
diameter--The range of the torsional channel shall be a minimum of +
3--The operational temperature range of the extensometer shall be -100
degrees F to +300 degrees F--The extensometer linearity shall not
exceed 0.30% with a hysteresis not to exceed 0.10%--The extensometer
shall interface directly to a MTS testH*8ar digital control system and
shall have the appropriate electrical connectors--The extensometer
shall be supplied with a certificate of linearity and gage factor and
an instruction manual with connectivity documentation--The extensometer
shall have a mechanical means of setting to axial gage length and
rotational zero and shall be attached to the test specimen by a maximum
of four contact points--The extensometer shall output one axial strain
signal and one torsional displacement signal--The extensometer shall
be supplied with MTS TestStar calibration files for two ranges of
operation and the Transducer calibration cartridges for the TestStar
Digital control system--This procurement is being conducted under the
Simplified Acquisition Threshold (SAT) portion of the Federal
Acquisition Streamlining Act (FASA) -- Note: This procurement is
sole-source based on system compatability requirements and predominant
experience -- Interested firms have until April 29, 1996, to submit in
writing their qualifications/capabilities in the critical areas
mentioned above -- Such qualifications/capabilities will be used solely
for the purpose of determining whether or not to conduct this
procurement on a competitive basis -- Responses received after April
29, 1996, or without the required information will be considered
nonresponsive to the synopsis and will not be considered -- A
determination by the Government not to compete this proposed contract,
on a full and open competitive basis, based upon responses to this
notice, is solely within the discretion of the Government -- See
Numbered Note 22 -- Oral communications are not acceptable in response
to this notice -- Responses must be submitted in writing --
Transmission by facsimile to 205-544-9080 or by Internet e-mail to
teresa.foley@msfc.nasa.gov is acceptable -- The solicitation and any
related documents to this procurement will be available over the
Internet -- These documents will be in ASCII format and reside on a
World-Wide Web (WWW) server, which may be accessed using client
browsers, such as, MOSAIC -- The WWW address, or URL, of the MSFC
Procurement home page is: ''http://procure.msfc.nasa.gov''. (0101) Loren Data Corp. http://www.ld.com (SYN# 0298 19960411\66-0001.SOL)
66 - Instruments and Laboratory Equipment Index Page
|
|