Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF APRIL 17,1996 PSA#1575

97th Contracting Squadron/LGCC, Bldg 318, 205 S 6th St., Altus AFB, OK 73523-5147

C -- A/E SERVICES FOR ELECTRICAL DISTRIBUTION SYSTEM MASTER PLANNING SERVICES, ALTUS AFB, OK Sol F34612-96-R0002, contact Gary Wynder, 405/481-7303, Contracting Officer, Larry D. Doles, 405/481-7303. Altus AFB, OK, is soliciting responses from Architectural & Engineering (A/E) firms for work associated with investigation, data collection, analyses, device coordination, drawing generation, and recommendation as part of an engineering and load study of Altus AFB's Electrical Distribution and Area Lighting Systems culminating in a formal report. Technical capabilities desired from the responses and the criteria which will the basis for selecting the firms are (in descending order of importance): 1) specialized experience in investigation, data collection and analysis of Army, Navy, utility company, municipality and rural cooperatives medium voltage distribution class electrical utility systems: 2) specialized experience in the investigation, data collection and analysis of Air Force medium voltage distribution class electrical utility systems; 3) broad experience in medium voltage distribution electrical utility studies, evaluations, reports, drafting and one-line generation using AUTOCADD and ARC-information; 4) specialized experience in medium voltage distribution class relay and protective and load break device sizing and coordination; 5) broad experience in design, construction, and operation in medium voltage distribution class electrical utility systems; 6) broad experience in medium voltage distribution electrical system, computer based data generation, manipulation, report interpretation and analysis; 7) professional qualifications of staff to include professional credentials, experience and training; 8) past performance on previous DoD and other contracts; 9) volume of work previously awarded to the firm to accomplish work in the required time; 11) proximity of firm in the general geographic area - first, 700 mile radius, then 1400 mile radius, and the other. The type of contract will be firm fixed-price contract. Estimated start of performance 15 Jun 96. Performance schedule is estimated to be as follows; Phase I (40% submission) 60 days, Phase II (55% submission) 60 days, Phase III (80% submission) 60 days, and Phase IV (100% submission) 45 days. Firms desiring consideration must submit Standard Forms 254, 255, and 1421's (if applicable) (see Note 24). If the firm desiring selection is located in a branch office, the SF 255 should reflect key disciplines and experiences for the branch office only. This announcement is not a request for proposal. Only those firms submitting appropriate date (i.e. SF 254, SF 255, etc.) within 30 calendar days from the date of this publication will be considered for selection. (106)

Loren Data Corp. http://www.ld.com (SYN# 0018 19960416\C-0005.SOL)


C - Architect and Engineering Services - Construction Index Page