COMMERCE BUSINESS DAILY ISSUE OF JUNE 5,1996 PSA#1609Bureau of Reclamation, 1150 North Curtis Road, Boise ID 83706-1234 28 -- GENERATOR STATOR SHROUDS, GRAND COULEE POWER OFFICE, GRAND
COULEE, WASHINGTON SOL 1425-6-SP-10-13960 POC Contact Becky Young
208-378-5107/Bryan K. Uba, Contracting Officer 208- 378-5110
Reclamation has 3 each 700 KVA generators in the 3rd Powerplant,
manufactured and installed by General Electric (GE), in the early to
mid 1970's, at Grand Coulee Dam, Washington. The lower shrouds on G-22,
G-23, and G-24 are failing and need to be replaced NLT September 30,
1996 because the generators will be out of service for stator repair
beginning in August, 1996 and need to be back on line by October, 1996.
The fiberglass shrouds shall be compatible to Canadian GE: 1 one-sided
shroud cover, Approx 4' L, GE DWG 767D225BA P08, and 1 loose joint,
DWG 783D981RW P01, and 40 self tap screws #10 X .062'' L, and assembled
to shroud cover IS 1 end tip seal. DWG 215A9944HJ P02-3PP G22-245
generator stator, for one sided lower shroud, one set consists of 45
each cover shrouds. Requirement is for two complete sets. Reclamation
intends to solicit and negotiate with only GE Canada under the
authority of FAR 6.302. Interested persons may identify their interest
and capability to respond to the requirement or submit proposals. This
notice of intent is not a request for competitive proposals. However,
all proposals received within 30 days after date of publication of this
synopsis will be considered by Reclamation. A determination by
Reclamation not to compete this proposed contract based upon responses
to this notice is solely within the discretion of Reclamation.
Information received will normally be considered solely for the purpose
of determining whether to conduct a competitive procurement. All
responders of this notice shall provide the following information: (A)
Commercial descriptive literature describing the proposed shroud; (B)
Describe how the proposed shroud will be modified to withstand the air
flows around the generators; (C) A list of customers (and point(s) of
contact) where shroud covers have been provided for generators; and (D)
a short explanation on how the proposed shroud will meet the other
requirements described above that are not covered by the commercial
literature. All responses must be received in writing NLT 30 days after
the publication date of this synopsis. Address responses to Bureau of
Reclamation, Attn: Code 3714, 1150 N. Curtis Road, Boise, ID,
83706-1234. (0155) Loren Data Corp. http://www.ld.com (SYN# 0180 19960604\28-0004.SOL)