COMMERCE BUSINESS DAILY ISSUE OF JUNE 19,1996 PSA#1619BOR - Snake River Area Office West, 214 Broadway Avenue, Boise, ID
83702 66 -- 66 - FURNISH MACHINE CONDITION MONITORING SYSTEM FOR ANDERSON
RANCH AND BLACK CANYON POWERPLANTS. SOL 142596SQ1100130 Vibration
monitoring equipment DUE 071196 POC Purchasing Agent, Marie Day,
208-334-1744, For technical info:, Mechanical Engineer, Ernie Bachman,
208-334-9561 The U.S. Bureau of Reclamation is seeking sources to
provide equipment for Machine Condition Monitoring systems within the
Snake River Area West Project. Purpose of this notice is to conduct a
market survey to identify potential sources to supply vibration
monitors for Units 1 and 2 at Anderson Ranch Powerplant, and Units 1
and 2 at Black Canyon Powerplant. These units have fluid film guide and
thrust bearings and operate at low speeds. Thus vibration monitors
measuring radial shaft vibration (runout) will be the primary
monitoring system. As a secondary system, velocity monitors will allow
the observation of operating frequency vibrations as well as
resonance, and hydraulic or magnetic imbalance. Velocity transducers
should provide a more linear frequency response for the lower
frequencies encountered with these hydro units than would an
accelerometer. These monitors installed on units at Anderson Ranch and
Black Canyon will keep constant check on the unit shaft vibration.
Analyses of the data generated by these monitors will allow plant and
project personnel to evaluate the performance of the unit's bearings
(upper and lower guides, turbine, and thrust) thereby increasing the
effective- ness of the preventative maintenance program. Bearing wear
and clearances will be monitored with these units. It will also, as an
added benefit, not only indicate trouble with all unit bearings;
thrust, turbine, etc., but also with the generator or turbine itself.
The output of these devices will be programmed into the plant's
supervisory control (automation) system. The vibration and velocity
monitors are part of the ongoing plant automation and are part of the
instrumentation needed for the eventual unmanning of the plant. The
units will include alarm and shutdown circuitry that will shut the unit
down prior to any major unit damage if excessive vibration is detected.
Specifications for this monitoring equipment will be available under
RFQ NO. 96-SQ-11-00130 with delivery scheduled for 8/16/96. Responses
are required by July 11, 1996. All responses will be fully considered
by the agency. Standard Industrial Classification code is 3829. (0169) Loren Data Corp. http://www.ld.com (SYN# 0311 19960618\66-0003.SOL)