COMMERCE BUSINESS DAILY ISSUE OF JULY 2,1996 PSA#1628National Institute of Standards and Technology, Acquisition &
Assistance Division, Building 301, Room B117, Gaithersburg, MD 65 -- LCX TEA/CDD 1242 EHR WITH GRADE 1 EEV MODEL 05-03 ARRAY WITH
OPTICAL NOSE CAMERA AND ST 1385 CAMERA SOL 52SBNB6C9201 POC Brenda K.
Lee (301) 975-6394, CO Lisa K. Jandovitz (301) 975-6344 The National
Institute of Standards and Technology (NIST) intends to negotiate with
Princeton Instruments, Inc., 3660 Quakerbridge Road, Trenton, NJ 08619
on a sole source basis to acquire an LCX-TEA/CCD-1242 EHR with Grade 1
EEV Model 05-30 array with Optical Nose Camera,ST-1385 Camera
Controller and IP-Lab Extension (controlling macintosh software). The
government requires delivery within 90 days after contract award with
a one year warranty to include parts and labor. This is a sole source
procurement in accordance with FAR 6.302-1, Only One Responsible
Source, because Princeton Instruments is the only source that can meet
all of these minimum technical specifications for a High-Resolution,
Large Format X-ray and Optical CCD Digital Camera and Control System.
The application of this camera is to perform phase-contrast imaging of
x-rays to characterize MEMs devices. This requires high spatial
resolution. This is best achieved through direct detection of x-rays
and will require using a large format CCD (about one square inch and,
because of the x-ray energies to be detected and resolution required,
pixel should be square and about 20 micrometer on a side. Smaller
pixels are not of interest since the electron cloud created by the
x-rays is not generally localized much smaller than this. The
sensitivity (quantum efficiency) is required to be high since some
applications will be at low light levels. A unique feature of the
Princeton Instruments camera is the ability to add a second A/D
converter in the camera controller should a different speed and bit
depth be required in the future. The minimum technical specifications
are as follows: 1. Camera Head--Thermoelectric Cooler to -40 degree
Celsius with air cooling, fan mounted and provided, to -50 degree
Celsius with water cooling, connectors provided, to -60 degree Celsius
with coolant circulation. Thermostating precision less than or equal
to 40 millidegrees Celsius. Must hold vacuum for greater than or equal
to six months. X-ray nose with Be window, Optical nose with
electromechanical shutter and Nikon bayonet lens mount. 2. CCD
Specifications: greater than one million pixels, at least 1000 pixel
rows, at least 1000 pixel columns, square pixels greater than 20 micro
meters on a side, 16-bit capable dynamic range, well capacity greater
than or equal to 5000,000 electrons, dark charge less than or equal to
six electrons/pixel-second, less than or equal to one percent response
linearity at one MHz digitization, read noise less than or equal to
six electrons at 50 kHz; less than 25 electrons at one MHz, special
high-resistance silicon for direct detection of x-rays. Spectral
response; X-Ray: greater than or equal to 40 percent quantum efficiency
at 8 keV, greater than or equal to five percent quantum efficiency from
3 to 20 keV. Visible: 300 nm to 1100 nm with optical nose. Pixel
defects: less than or equal to one black column defect, zero white
column defects, zero row defects, less than or equal to three black
clusters of three pixels each, less than or equal to two black clusters
of five pixels each, less than or equal to ten white pixels. 3. Camera
Controller Specifications: High-speed interface controller capable of
data rates up to ten Mbytes/sec, provides power, thermostating,
shutter control and timing signals to the detector head, temperature
setting and readout on front panel, programmable TTL input and output
ports, 14 bit A/D at one MHz and the capability to add a second A/D
converter, e,g, 16 bits at 150 kHz, single controller board compatible
with Macintosh expansion (bus) slot. Macintosh compatible software for
full camera control and image manipulation, Software environment
permits user extensions and scripting. 4. Critical components must be
assembled in clean room and system must include full test report of
actual performance (Read noise, Dark noise, linearity, and Pixel
defects); typical specifications are not acceptable. Interested
offerors may identify their interest and capability to respond to the
requirements by submitting a capability statement. The capability
statement must provide adequate information and qualifications of your
ability to provide the requested system in order for the Government to
consider whether to open this request for competition. However, all
capability statements received within 45 days after date of this
synopsis, will be considered by the Government. See Note Numbered 22
(0180) Loren Data Corp. http://www.ld.com (SYN# 0383 19960701\65-0001.SOL)