Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF JULY 8,1996 PSA#1631

AFFTC/PKA Directorate of Contracting, 5 S Wolfe Ave, Edwards AFB CA 93524-1185

66 -- ANALOG OSCILLOSCOPE AND RACKMOUNT SOL F04700-96-T-7148 DUE 070896 POC Cheryle Fowler, Purchasing Agent, (805) 277-3900 x2247 John Adair, Contract Officer, (805) 277-3900 x2230. The Air Force Flight Test Center (AFFTC) has a requirement for 30 analog 100 MHz Bandwidth Oscilloscopes. The government is interested in locating qualified sources able to provide this equipment. These units are required to provide 4 channel inputs, BNC connectors, front panel. They shall have the following trigger modes available, AUTO, NORM, TV-V, TV-H, and SINGLE. Maximum input voltage shall not be less than 400 VDC. CRT Display shall provide a range of 50HZ to 100MHz in 4 digits. Size: Maximum of 5.25 inches high, 15 inches deep. Must be adaptable to 19 inch rack mount. Environmental: Operating temperature: 0-50 degree C(operating). Vibration: Shall meet the requirements of MIL-E-5400T, paragraph 3.2.24.5, Curve IIa, for jet aircraft. All data transfers, manipulations, processing, visualizations and all data storage and retrieval shall be within specs during the entire range of vibration. Cooling: Cooling air intake and exhaust ports shall be on the rear of the equipment. No external refrigeration shall be required to meet the operating temperature requirements. Humidity: Up to 90%, non condensing. Altitude: Unit must operate up to 15,000 feet per the altitude requirements of MIL-E-5400T for Class 1B equipment. Power: 105 to 120 VAC, 48-440 Hz. Parts: all electronic components and electrical hardware, such as but not limited to semiconductors, microelectronic devices, capacitors, resistors, connectors, etc., shall meet the requirements of MIL-E-5400T. All electronic devices shall be solid state. Corrosion Resistance: Materials shall be of corrosion-resistant types or shall be processed to resist corrosion for the complete life cycle of the equipment in the specified environments of a warehouse, nonfighter jet aircraft and electronics lab. Selection and protection of dissimilar metal combinations shall be in accordance with MIL-STD-454, Requirement 16. Materials: Gold, nickel, chromium, rhodium, tin, lead-tin alloys, or sufficiently thick plating of these metals are satisfactory without additional protection or treatment other than buffing or cleaning. No components containing polyvinyl chloride (PVC) shall be used. External Connectors: External connectors shall be positive locking and quick disconnect type, terminal boards or terminal strips shall not be used. External multipin connectors shall have individually removable and replaceable pins. All external chassis mounted connectors shall have female sockets. Internal Connectors: Quick disconnect type connectors shall be used for internal conectors to all lowest replaceable assemblies. Connectors must be sufficiently secured to operate in a sustained vibration environment over the expected life cycle of the equipment. Wiring: All wiring used must be of sufficient size to carry the maximum expected current. In the case of overcurrent, the wire must not create a fire hazard, thus wires suspected of this capability shall be fused to prevent overcurrent. NO PVC INSULATED WIRE MAY BE USED. All external wire shall be in accordance with MIL-W-5088. Accessibility: Accessibility shall be in accordance with MIL-STD-454, Requirement 36. Specific subassembly arrangement shall be such that access to each module does not require the removal of adjacent modules or parts other than access panels and connectors. Routine maintenance or calibration of the equipment while in the operational installed field position shall not require the removal of any modules or parts except the removal of access panels. Test Points: Provisions for test points shall conform to MIL-STD-454, Requirement 32. Test points shall provide for ease of field testing and maintenance. Control Panels: The equipment's control panel shall conform to MIL-STD-454, Requirement 28. Explosion Proofing: The system shall be designed to prevent ignition of any gaseous atmosphere by arcing components. The Simplified Acquisition Procedure (SAP) will be used in awarding this contract by written quotation. Based on responses to this synopsis, this requirement maybe set aside for small business, reserved for the 8(a) program, or be competed under full and open competitive procedures, SIC code 3825, size standard 500 employees. Sources responding to this market survey must provide a capabilities statement and descriptive literature addressing the above requirement by 15 July 1996. Include relevant background and experience, provide contract numbers, names and phone numbers of contracting office POC, names and phone numbers of technical office POC for each contract. Also provide your business size and type of business (e.g. DB, SDB, 8(A), LB, etc.) Submit written information to Cheryle Fowler, AFFTC/PKAB, 5 South Wolfe Ave, Edwards AFB, CA 93524-1185. Fax responses to (805) 258-7810. Telephone requests to be placed on the mailing list will not be honored. (0185)

Loren Data Corp. http://www.ld.com (SYN# 0415 19960705\66-0012.SOL)


66 - Instruments and Laboratory Equipment Index Page