|
COMMERCE BUSINESS DAILY ISSUE OF JULY 9,1996 PSA#1632Directorate Of Contracting, Oo-Alc 6050 Gum Lane/Bldg 1215, Hill Air
Force Base, Ut 84056-5825 16 -- PISTON, SNUBBER ASSE SOL F42630-96-Q-69961 DUE 081396 POC For
copy, PKX-2/Pamala Chaffee/(FAX)801-777-7522, For additional
information contact Landing Gear/Photo/Likl/(801)777-6501 Item 0001 NSN
1620-00-869-9881 P/N: 90-8652-3, Material: 4340 steel. Dim: ID. 940'',
OD 1.362''. Used on the MLG snubber. 270ea. Applicable to: Kc-135.
Destn: Hill Air Force Base, Ut 84056-5825. Delivery: 30 Apr 97 197 ea
31 Jul 97 73 ea Item 0002 data, 1 lot Qualification requirements:
Sources must be qualified prior to being considered for award. The
solicitation will contain instructions for obtaining further
information on this requirement. The requirements of FAR 9.202(A) have
been completed and copies of the qualification requirements and
standards may be obtained as described in the solicitation. These
qualification requirements apply to line item(s) all The approximate
issue/response date will be 24 Jul 96. The anticipated award date will
be 13 Aug 96. Written procedure will be used for this solicitation.
To: Hydromach Inc, Canoga Park Ca 91304-1416. To: Yeager Mfg Co Inc,
Anaheim Ca 92806-1229. To: B & B Manufacturing Co, Valencia Ca
91355-1209. To: Loud Engineering & Mfg Inc, Ontario Ca 91761-0934. To:
Hydro Mill Co, Chatsworth Ca 91311-5202. First article test required.
No telephone requests. Only written or faxed requests received
directly from the requestor are acceptable. All responsible sources
solicited may submit a bid, proposal, or quotation which shall be
considered. Award will be made only if the offeror, the
product/service, or the manufacturer meets qualification requirements
at the time of award in accordance with FAR clause 52.209-1. The
solicitation identifies the office where additional information can be
obtained concerning qualification requirements is cited in each
individual solicitation. It is suggested that small business firms or
others interested in subcontracting opportunities in connection with
the described procurement make contact with the firm(s) listed. Request
for copies of solicitations must reference the entire solicitation
number, including purchasing office identification number. To expedite
your request, limit the number of individual solicitation numbers
requested per letter to not more than 10. Don't request information on
this requirement until after the issue date. This proposed procurement
is under a 100 percent small business set aside, the size standard for
which is 1,000 employees. An Ombudsman has been appointed to hear
concerns from offerors or potential offerors during the proposal
development phase of this acquisition. The purpose of the Ombudsman is
not to diminish the authority of the program director or contracting
officer, but to communicate contractor, concerns, issues,
disagreements, and recommendations to the appropriate government
personnel. When requested, the Ombudsman will maintain strict
confidentiality as to the source of the concern. The Ombudsman does not
participate in the evaluation of proposals or in the source selection
process. Interested parties are invited to call Jack S. Jones if your
concerns are not satisfied by the contracting officer (801)777-6991.
Data is claimed to be proprietary to Boeing and is protected under the
''Government Purpose License Rights'' (GPLR). The right of the
government, to use that data to purchase this part from additional
sources has been established under the ''Government Purpose License
Rights'', settlement agreement in CL. CT.#309-89C., to provide the DOD
procuring agencies the use of the data claimed to be proprietary by
Boeing for competitive reprocurement of replenishment spares. This part
required engineering source approval by the design control activity in
order to maintain the quality of the part. Existing unique design
capability, engineering skills, and manufacturing knowledge by the
qualified source(s) require acquisition of the part from the approved
source(s). The approved source(s) retain data rights, manufacturing
knowledge, or technical data that are not economically available to the
Government, and the data or knowledge is essential to maintaining the
quality of the part. An alternate source must qualify in accordance
with the design control activity's procedures, as approved by the
cognizant Government engineering activity. The qualification procedures
must be approved by the Government engineering activity having
jurisdiction over the part in the intended application. Beginning May
1996, Ogden Air Logistics Center/PK (00-ALC/PK), Hill Air Force Base,
Utah began a ''phase in'' process, distributing drawings associated
with solicitation packages on CD ROM. Aircraft, Commodities and Missile
Procurements will be affected. The ''phase in'' process will be by NSN.
During this period data may be available on CD-ROM, Floppy Disk, or
aperature cards. CD-ROM is the medium of preference. After SEP 1996
data available by CD-ROM will gradually increase. The minimum set-up
requirements to view the drawings supplied by OO-ALC areas follows: 386
INTEL 33MHZ processor or higher; 8 MEGABYTES RAM; Any size hard drive;
CD ROM reader (1X, 2X OR 4X); 14'' color monitor (17'' is recommended)
DOS 5.0 or higher; windows 3.1 or higher, UNZIP software. To provide
comments please contact Brad Bennett (801)777-0889 by 15 April 1996.
For technical information please contact Kim Call at 801-777-6225.
Limited or Rightsguard Data will be provided on aperature cards until
further notice. See Note (s) 1. (0187) Loren Data Corp. http://www.ld.com (SYN# 0333 19960708\16-0001.SOL)
16 - Aircraft Components and Accessories Index Page
|
|