COMMERCE BUSINESS DAILY ISSUE OF JULY 25,1996 PSA#1644Arnold Engineering Development Center, ATTN: PKP, 100 Kindel Drive,
Suite A332, Arnold AFB TN 37389-1332 66 -- SCIENTIFIC GRADE SLOW SCAN CAMERAS SOL F40650-96-R-0030 DUE
090696 POC Kathy P. Swanson, Contract Specialist, (615) 454-7841 This
procurement is for a scientific grade slow scan TE/CCD-1024SB camera
for use in acquiring images of models covered with pressure sensitive
paint (PSP). The cameras must have SITe model ST-003 grade 1
back-illuminated array with 1024 x 1024 pixel format, 24 x 24 um pixel
size, 24.6 x 24.6 mm active area. The peak quantum efficiency should
be greater than 30% from 350-950 nm, 60% from 400-800 nm, and 70% from
500-750 nm. The camera controller should have the capability for 2
analog to digital converts, remotely selectable via software. The
connection to computer must be capable of transmitting over a distance
of at least 300 ft. and up to 2,000 ft. via fiber optic cable. The
cameras must be compatible with the parallel data acquisition on a
Silicon Graphics Challenge L workstation. Quantity - 7 each. Delivery
to Arnold AFB, TN, will be 90 days from contract award. Intended source
is Princeton Instruments, 3660 Quakerbridge Road, Trenton, NJ 08619,
609-587-9797. See Note(s): 22. (0205) Loren Data Corp. http://www.ld.com (SYN# 0515 19960724\66-0010.SOL)
66 - Instruments and Laboratory Equipment Index Page
|
|