COMMERCE BUSINESS DAILY ISSUE OF AUGUST 2,1996 PSA#1650Sacramento Alc/Bc, 5033 Roberts Avenue/Suite 1, Mc Clellan Air Force
Base Ca 95652-1326 59 -- COCKPIT VOICE RECORDER POC For copy, contact the info office
indicated., For additional information contact
Aita.Bc2/Bc/(916)643-0728 Item 0001 NSN 5900-VF- - See below for
description ea. Destn: Mc Clellan Air Force Base Ca 95652-1326. Item
0002 17. This is a market survey (Ref. MS96206-01) under the
Competition in Contracting Act, effective 1 April 1985. This is not an
Request For Proposal (RFP) or Invitation For Bid (IFB). Solicitation
is not available. Be advised that this is used for planning or
information gathering purposes only. The Government does not intend to
award a contract on the basis of this request or otherwise pay for the
information which you provide. The following descriptions are offered
as a basis in which to formulate a reply to this notice. The Sacramento
Air Logistics Center (SM-ALC) is seeking to identify sources of supply
that can provide Cockpit Voice Recorder (CVR), to replace Model
A100-A, NSN: 5835-01-128-7757. The CVR will be used in at least
aircraft C-130s, C-141s, C-5A&B, C-17s, and E-3s. The CVRs shall need
to be currently certified to Federal Aviation Administration (FAA)
Technical Standard Order (TSO) TSO-C123. The CVR system equipment
individual items shall have no larger valued power requirement than
that required for the currently fielded COTS product Fairchild Aviation
Div. Model A-100A CVR system equipment corresponding item. Do not
disturb weapon system equipment power budget considerations. The
aircraft AC electrical system is 400 Hz 115 VAC. The Model A100A power
constraint is 115 VAC, 400 Hz., 50 W maximum with 20 W maximum normal
operation mode. Alternative optional accessory Inverter Power Supply
shall be available. This option shall be for aircraft systems that
operate on 28 volts DC (VDC). The power supplied form 28 VDC shall
supply 21 (Watts) W maximum normal operation power with an inverter
conversion to the 115VAC required CVR system operating voltage
requirement. The currently fielded Control Unit power requirement is
+18 VDC. The CVR system equipment shall not exceed the weight limits
specification for the currently fielded Model A- 100A CVR system
equipment. The requirement for memory storage media shall be Flash
Memory (Solid State Non-Volatile Memory). Additional information are
available to further describe the CVR system. Companies interested in
this survey are encouraged to request technical specification data by
contracting the Dept. of the Air Force, SM-ALC/BC, Attn: Mike Aita,
5033 Roberts Ave., Suite 1, McClellan AFB, CA 95652-1326 no later than
31 August 1996. (0213) Loren Data Corp. http://www.ld.com (SYN# 0409 19960801\59-0008.SOL)
59 - Electrical and Electronic Equipment Components Index Page
|
|