COMMERCE BUSINESS DAILY ISSUE OF AUGUST 16,1996 PSA#1660Operational Contracts; AFDTC/PKO; 205 W. d Avenue, Eglin AFB FL
32542-6862 66 -- GENERIC FLIGHT TERMINATION SYSTEM BATTERIES SOL F08651-96-Q-9633
DUE 083096 POC TSgt Rob Swett, (904) 882-9254, Contract Specialist;
Contracting Ofiicer, Bonnie J. Fitch. The Air Force Development Test
Center (AFDTC) intends to solicit competitively under Federal
Acquisition Regulation (FAR) Part 12, Acquisition of Commercial Items,
for 24 batteries for a Generic Flight Termination System (GFTS) to be
used by munitions test programs. Minimum specifications for the
batteries include both functional and environmental requirements. The
unit shall comply with all Flight Termination Battery requirements as
defined in the Range Commanders Council document Flight Termination
System Battery Guidelines, Document 318-89. The unit's shall have a
minimum output voltage of 24 volts and a maximum output voltage of 35
volts. The unit shall have a minimum lifetime of 15 minutes while
providing at least .5 amperes of steady-state current and also during
this lifetime the batteries must be capable of providing at least 4 10
amp pulses each having a 5 second duration, two of which, must be
provided at the end of the batteries 15 minute life cycle. The
batteries must have no greater than a 2 second rise time to a 24 volt
level after receiving an activation signal. The activation mechanism
must comply with all specifications in MIL-STD-1512. The units must
have a visible activation indicator and an electronic activation
indicator. The unit shall not consume greater than 19 cubic inches. Due
to the project's abbreviated time frame, the batteries sought shall
have undergone and passed a number of environmental qualification tests
verifying proper operation under the following conditions: humidity,
explosive atmosphere, dust/fine sand, EMI/EMC, salt, fog, fluid
contamination and fungus. Additionally, the unit must have undergone
and passed testing in the areas of vibration, shock, temperature,
acceleration, pressure, acoustic noise, and explosive atmosphere
commensurate with acceptance levels established during Phase I of the
Generic Flight Termination System effort. These levels will be made
available upon request. Delivery is required by April 1997. Technical
questions may be directed to Mr. Matthew D. Rowley, (904) 882-2337.
Contracting questions may be directed to Rob Swett at (904) 882-9254.
Replies to this synopsis should be provided to AFDTC/PKOS, 205 W. D
Ave, Suite 541, Eglin AFB FL 32542-6862. All responsible sources may
submit an offer which will be considered. (No contract award will be
made on the basis of bids/proposals received in response to this
synopsis.) Firms responding to this solicitation should reference
F08651-96-Q-1257 and indicate whether they are or are not a small or
small disadvantaged business concern as defined in FAR 52.219-1 and
52.219-2. The Air Force reserves the right to consider a small business
set-aside based on responses hereto. Requests for copies of this
solicitation must be in writing, but may be sent by fax to (904)
882-9442. Telephone requests will not be honored. (0227) Loren Data Corp. http://www.ld.com (SYN# 0409 19960815\66-0005.SOL)