COMMERCE BUSINESS DAILY ISSUE OF AUGUST 22,1996 PSA#1664Contracting Officer, Naval Hospital, Brewster Blvd, Camp Lejeune, NC
28547-0100 W -- RENTAL OF AND PREVENTIVE MAINTENANCE CONTRACT FOR AN IMMUNOASSAY
ANALYZER SOL N68093-96-Q-0135. DUE 091596. POC R.L. Olson,
910-451-4927 or Contracting Officer, Pearl L. Robinson, 910-451-4924.
The U.S. Naval Hospital, Camp Lejeune, NC, intends to issue a sole
source purchase order to Abbot Laboratories, Diagnostic Division,
Department 943, Bldg AP6C, 100 Abbott Park Road, Abbott Park, IL
60064-3500 for the rental and preventive maintenance and service calls
for an Abbott AxSYM system third generation fully automated
immunoassay analyzer. Note 22 applies, however, all offers received
within 15 (in lieu of 45) days after the date of publication of
original synopsis will be considered by the government. Analyzer is
bi-directional computer interface with a RS232 interface board and
standard ATSM computer interface capable of operating with a
Massachusetts University Medical Programming System with working
operation interface with documentation compatible with current LIS/HIS
(CHCS). Accomodates all primary tube sizes, can use dedicated sample
cups, can read all common barcode symbologies. Stores up to 20 user
chosen reagent kits of 100 tests on board, up to 60 primary/aliquot
tubes or 90 sample cups can be loaded at one time. Walk-away capability
of up to 3 hours. 15 minute or less turnaround time for STAT assays,
total of 80-120 test per hour. Analyzer must have current capability of
performing Ultrasensitive Thyroid Stimulating Hormone (UTSH), Total T3,
Total T4, Free Thyroxin4 (FT4), T-Uptake, Ferritin, Leutenizing Hormone
(LH), Follicle Stimulating Hormones (FSH), Prolactin, Beta Subunit of
Human Chorionic Gonadotropin (BETA-HCG), CKMB, and thereapeutic drug
monitoring of drugs Theophylline, Carbamazepine, Gentamicin, Phenytoin
(Dilantin), Phenobarbital, Vancomycin, Quinidine, Digoxin, Valproic
Acid, Tobramycin, and Carcinoembryonic Antigen (CEA) Tumor Markers
(PSA, CEA, and AFP). Capable of Microparticle Immunoassay (MEIA),
Fluorescence Polarization Immunoassay (FPIA). Capabilities include/will
include: endocrine function, abused drugs, cancer markers, STD markers,
cardiovascular, therapeutic drug monitoring, hepatitis/retrovirus,
congenital markers, fertility markers, metabolic markers. The analyzer
will not use radioactive regeants, can operate in batch or random
mode, have on-instrument storage for a minimum of 2000 tests, be
capable to store at least 4000 patient results, perform automatic
on-instrument autodilution for linear high BETA-HCGS, have
on-instrument reagent storage for a minimum of 2000 tests, have
on-board quality control program to store at least 5000 data points and
capable of printing Levy-Jennings charts, be capable of storing 4 lot
numbers and 4 calibration curves of reagents for the same test at any
given time, calibration must be stable for 2 weeks, have individual
reagent packs with sufficient reagents for at least 50 tests, be able
to read bar codes on both patient sample tubes and reagent packages.
The maintenance/service calls shall include but is not limited to the
following: includes 2 scheduled preventive maintenance calls during the
year, unlimited service calls 7 days a week, 24 hours a day, with
response time within 24 hours after call. The resultant contract will
be a firm fixed price contract for one basic year, 96OCT001 to 97SEP30,
and one option year, 97OCT01 to 98SEP30. (229) Loren Data Corp. http://www.ld.com (SYN# 0165 19960821\W-0001.SOL)
W - Lease or Rental of Equipment Index Page
|
|