COMMERCE BUSINESS DAILY ISSUE OF SEPTEMBER 5,1996 PSA#1673Room 6845, JEH-FBI Bldg., 935 Pennsylvania Ave., NW, Washington DC
20535 58 -- LABORATORY DIGITAL SIGNAL PROCESSORS SOL RFQ-60280 DUE 092396
POC Deanna D. Davis, Contract Specialist, (202) 324-9219. This is a
combined synopsis/solicitation for commercial items prepared in
accordance with the format in Subpart 12.6, as supplemented with
additional information included in this notice. This announcement
constitutes the only solicitation; written quotations are being
requested and a separate written solicitation will not be issued. This
solicitation is being issued as Request for Quotation (RFQ) 60280.
This acquisition will be processed in accordance with Simplified
Acquisition Procedures (SAP) for Small Business-Small Purchase
Set-Aside. Standard Industrial Classification is 3825. The requirement
consists of nine (9) Laboratory Digital Signal Processors, Brand Name
(DAC RCW320T) or Equal that meets the following salient
characteristics: Must be fully compatible with Tektronix TM500 series
power modules (double width), Must not weigh more than 16 lbs, Must
contain at least a 256 order adaptive digital filter with adjustable
filter order, adjustable prediction delay and have adapt/freeze
function, Must have an adjustable comb filter with notch depth and
upper notch frequency limit control, as well as adjustable notch width,
Must have a band width of at least 30 to 7000 Hz (analog), Dynamic
range greater than 80 db, Line input adjustable from -6 to +8 dbm, Line
output (0 dbm), Headphone output (adjustable), Highpass and Lowpass
filter with at least 55 db attenuation per 300 Hz. Also, should have
selectable cutoffs in 50 Hz steps, Bandpass and bandstop filter with
variable high and low cutoffs (greater than 50 db rolloff per 350 Hz),
Dual 150 Hz wide notch filters with centers adjustable from 250 to
6500 Hz (45 db notch depth), AGC with adjustable attack and time
constant adjustable from 10 to 400 msec and have adjustable gain,
Signal generator capable of generating sinewave, white and pink noise
with adjustable levels. Warranty period one (1) year or more. Ship to
address: Engineering Research Facility, Quantico, Virginia 22135.
Specify if the prices quoted are freight on board Destination or
Origin/Pre-Paid. Delivery to be made 45 days after receipt of order.
All responsible sources may submit a written bid within fifteen days
after date of publication to the above address no later than September
23, 1996, 4:30 p.m., eastern standard time which, if timely received
shall be considered by the agency (extra days have been added to the
response time in order to allow for transmittal time). Bidders are
hereby notified that bids that are not received by closing date/time
will be considered late in accordance with the Federal Acquisition
Regulation. All bids shall be clearly marked with RFQ number 60280. Any
questions concerning the specifications shall be put in writing. The
point of contact for all information regarding this acquisition is Ms
Deanna D. Davis, Contract Specialist, at the address listed above and
fax (202) 324-8040/8031. Award to be made one (1) day after closing.
See Numbered Note 1. (0247) Loren Data Corp. http://www.ld.com (SYN# 0209 19960904\58-0002.SOL)