COMMERCE BUSINESS DAILY ISSUE OF SEPTEMBER 6,1996 PSA#1674USDA, Food Safety and Inspection Service, ASD, PCS, Room 2161 South
Building, 1400 Independence Avenue SW, Washington, DC 20250-3700 65 -- ROBOTICES FOR PREPARATION AND PROCESSING OF SAMPLES SOL
FSIS-23-W-96 DUE 091796 POC Contact Point, Tawana Nathan, (202)
720-9891 The U.S. Department of Agriculture, Food Safety and Inspection
Service (FSIS) intends to award a contract to ZYMARK CORP for one 50432
Microplate Core; one 53069 Room Large Capacity Micro Assay Storage
Carousel; one 50444 Stand Alone Rapid Plate inclues 54539 Zymark
Reservoir & Computer; six 53336 Auxiliary Deep well racks; 10 53335
Auxiliary pipet tip racks; one 49846 Microplate Turntable; one 50451
Microplate Bar Code Reading Module; one Large Capacity Micro Assay
Storage Carousel; one 53073 Temperature Controlled Large Capacity
MicroAssay Storage Carousel; one 50439 Multi Reagent Dispensing Module
includes: 91139 (2) Reagent Addition Modules; one 91139 Reagent
Addition Modules; one 56982 System V Controller 5-slot; and one 50444
Stand alone Rapid Plate. FSIS intends to negotiate on a sole-source
basic in accordance with 41 U.S.C. 253(c)(1). The system is required to
automate the Salmonella ELISA screening procedure at the Eastern
Laboratory, to fulfill the requirements of the Pathogen Reduction;
Hazard Analysis and Critical Control Point Systems Final Rule. The
ZYMARK automated system is consistent with existing manual
microbiological methodology procedures. To be considered, the system
must be a commercially available devices (robotics) that can perform
the following operations: 1) cover and uncover deep well microliter
plates; 2) manipulate (physically move from one location to another)
deep well microliter plates; 3) manipulate (aspirate and dispense)
aseptically liquid samples of approximately 1-ml volume by pipette; 4)
dispense liquid reagents (approximately 2.0 ml) into a test plate; 5)
dispense small volumes of liquid samples (10-500 microliter volumes)
into a 96-well microliter plate; 6) physically manipulate (move from
place to place) 96-well microliter plates; 7) maintain sample
throughout 250-300 samples per day continuous operation. This may
require processing multiple batches daily; and 8) maintain sample
integrity by preventing cross-contamination and environmental
contamination. Only fully developed, commercially available systems
shall be considered. All interested concerns must identify their
interest in writing and fully document their capability to meet the
agency's requirements by forwarding a detailed response within 10 days
of publication of this notice. All responses must be in writing and
may be faxed to 202-690-1814. All proposals from responsible sources
will be considered by the Agency. If no affirmative written responses
are received within 10 days of publication of this notice to determine
that a comparable source is available, or is more advantageous to the
Government, negotiations will take place with Zymark Corporation.
(0248) Loren Data Corp. http://www.ld.com (SYN# 0265 19960905\65-0002.SOL)