COMMERCE BUSINESS DAILY ISSUE OF SEPTEMBER 9,1996 PSA#1675Phillips Laboratory/PKVA, Directorate of Contracting, 3651 Lowry Avenue
SE, Kirtland AFB NM 87117-5777 J -- REPAIR OF A RESEARCH ELECTRON ACCELERATOR SOL F29601-96-R-0017
POC S. Knickerbocker, Contract Specialist 505-853-3238, Barbara M.
Steinbock, Contracting Officer, 505-846-5935. TITLE: REPAIR OF A
RESEARCH ELECTRON ACCELERATOR Solicitation F29601-96-R-0017. DUE: 03
October 1996. POC Shirlee Knickerbocker, Contract Specialist,
(505)853-3238 and/or Barbara M. Steinbock, Contracting Officer,
(505)846-5935. Notice of intent to award sole source to Radiation
Dynamics,Incorporated for the repair of the CW Electron Accelerator.
The electron accelerator, model EA 1.5, was manufactured in the late
1950s by Radiation Dynamics, Incorporated. REQUIREMENTS: PL/VTET
requirements for the electron accelerator are operation at a minimum
end-point energy of one million electron volts (1EMeV) at an output
current of 1 milliampere. This is a continuous-operation (CW)
accelerator as opposed to a pulsed accelerator. REPAIR DESCRIPTION: The
main cascaded rectifier system of the aforementioned electron
accelerator no longer operates properly. The existing rectifier system
is driven by a high-frequency oscillator at a radio-frequency (RF) of
300 kilohertz. Power to the rectifiers is capacitively coupled from an
internal RF power supply to an array of corona rings thereby
eliminating the need for conventional filter condensers. The present
rectifier system configuration has 32 vacuum tubes (Dunlee VR-24),
which are no longer manufactured nor otherwise available. Therefore,
the present rectifier system must be replaced with a solid state
rectifier system that has been engineered to properly power the
accelerator. Since the existing system uses the existing corona ring
assembly to provide impedance matching between the rectifier and the
power supply, the replacement system must be impedance matched as well.
Assembly is needed to match the capacitive coupling characteristics of
the tank oscillator of the electron accelerator's present
configuration. The high frequency RF power is coupled through a
solenoidal RF transformer which must be compatible with the new
solid-state rectifier system. This requirement makes the replacement of
this transformer likely to ensure compatibility with the power and
impedance requirements of the new rectifier assembly. With the change
of the rectifier system, new optical monitors will be required to
detect arcing (corona current) within the accelerator. These monitors
shall be integrated into the operation of the accelerator to prevent
excessive corona current from being drawn and thereby prevent damage to
the accelerator. An organizational conflict of interest clause may be
required in any resulting contract to provide access to the
manufacturer's proprietary data. An Ombudsman has been appointed to
hear concerns from offerors or potential offerors during the proposal
development phase of this acquisition. The purpose of the Ombudsman is
not to diminish the authority of the Program Director or Contracting
Officer, but to communicate contractor concerns, issues, disagreements,
and recommendations to the appropriate government personnel. When
requested, the Ombudsman will maintain strict confidentiality as to the
source of the concern. The Ombudsman does not participate in the
evaluation of proposals or in the source selection process. Interested
parties are invited to call the PL Ombudsman, Colonel James Ledbetter
in the Operations Directorate (505) 846-4964. The Ombudsman should
only be contacted with issues of problems that have been previously
brought to the attention of the Contracting Officer and could not be
satisfactorily resolved at that level. For Contracting issues, please
contact Barbara M. Steinbock, Contracting Officer, at (505) 846-2246.
For Technical issues, please contact Mr. William Kemp, Project Officer,
at (505) 846-4500. Mail all requests for the solicitation referencing
RFP number F29601-96-R-0017 to: Phillips Laboratory/PKVA, Attn.: S
Knickerbocker. (Note 22 and 26 of this CBD shall also apply). (0249) Loren Data Corp. http://www.ld.com (SYN# 0032 19960906\J-0002.SOL)